HI520 is an advanced process controller that can be configured for applications requiring monitoring and/or control of four main water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen.

  • Waterproof IP65 (Nema 4X) enclosure
  • Multi-color LED status indicators & audible alarm
  • Universal mounting kits available with wall, pipe, and panel mounting options
    (All mounting kits must be ordered separately.)

Estimated delivery: 8 - 9 September

Inquire Now

Description:

HI520 is an advanced process controller that can be configured for applications requiring monitoring and/or control of four main water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen. This controller features a digital probe input(s) that automatically detects and updates the controller with the parameter that it measures.

HI520 is Hanna’s first dual-input process controller that accepts virtually any combination of compatible probes. Designed to adapt to unique process control requirements, users have the option to enable or disable each channel independently.

Additionally, HI520 introduces enhanced industrial control by operating a control-loop system whereby users have the option to run channel control either independently or configure to be triggered sequentially upon reaching the other channel’s set point(s) (1, 2, or both). The device operates a logical channel with built-in mathematical functions. This function is intended for when the controller works as an analyzer for monitoring high/low parameter levels between two identical inputs with identical measuring configurations.

HI520

Control Modes

Set points for control operations can be configured to be on/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.

Hold Function

Hold can also be triggered manually and by using and external digital input for disabling control mode when performing maintenance.

Configurable Alarm System

Configurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.

Auto-cleaning cycle

The cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.

hi520

Relays

Available with up to five control and one alarm electromechanical relays.

Analog Outputs

Up to four galvanically isolated analog outputs for control of pumps and valves.

Digital RS485 Output

Can daisy-chain up to 32 devices to a remote monitoring system.

Digital Inputs

Two digital inputs available for modes including disabling, cleaning and placing the controller into hold status.


HI520

Large LCD

The LCD displays measurement information along with indicators of potential problems. The DIAG key then provides details of the issue.

HI520

Data-logging

Store info at selectable intervals along with relay control settings and calibrations data. Up to 100 lots, each holding 8600 records. Transfer to a flash drive as a .csv file using the USB Type-C port.

HI520

Help Button

Using the help and diagnostic button (? DIAG) will provide information related to errors or in setup mode, information about settings.

Specifications

SKU HI520
Name Dual-Channel Universal Process Controller for Industrial Applications – HI520
Channels 2
Display Graphic LCD, 128 x 64 pixel B/W with backlight
Digital Inputs 2 independent, galvanically isolated inputs (configurable for Hold & Cleaning functions)
On state 5 to 24 Vdc, low or high level active
Analog Outputs 2 or 4 independent, galvanically isolated outputs 0 – 22 mA configurable as: 0 – 20 mA;
4 – 20 mA 22 mA as alarm signal, configurable option
Digital Communication RS485 serial port – Remote monitoring and control USB-C port – Retrieve log files and firmware upgrading
Relays Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions
Electromechanical relay SPDT and SPST contact outputs 5A – 250 Vac; 5A – 30 Vdc (resistive load)
Fuse protected 5A, 250V slow blow fuse
Alarm Relay for All Measurement Alarms Electromechanical relay SPDT contact output 5A – 250 Vac; 5A – 30 Vdc (resistive load) Fuse protected: 5A, 250V slow blow fuse
Data Logging Interval log, up to 100 files, maximum 8600 records on each stored file. When the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one.
Event log, maximum 100 records. When the maximum limit is reached, the last record overwrites the oldest one.
Power Supply 100 – 240 Vac ±10%; 50/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)
Power Consumption 15VA
Installation Category II
Environment -20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing
Enclosure* Single case ½ DIN, type 4X, IP65 ingress protection
Weight Approximately 1.6 kg (3.5 lb.)
Dimensions Width: 144.0 mm (5.7 in.)
Height 144.0 mm (5.7 in.)
Depth 151.3 mm (6.0”)

Manuals

Dual-Channel Universal Process Controller for Industrial Applications – HI520

Bestsellers

Inquire Now

Chlorine, pH, ORP, and Temperature Analyzers - PCA300 Series

The Hanna Instruments PCA310, PCA320, PCA330 and PCA340 series of chlorine, pH, ORP and temperature analyzers are microprocessor controlled, process analyzers which continuously monitor a sample stream for chlorine content, pH, ORP and temperature values.
  • 4 models available for monitoring chlorine, pH, and ORP levels
  • Two separate selectable 0-20 or 4-20 mA signal output (PCA340 only)
  • User-friendly interface simplifies setup and maintenance
Inquire Now

pH Analog Controller with Self-Diagnostic Test – HI8710

2,140 AED
HI8710 is a panel mounted pH controller with self-diagnostic test capabilities. Users can set: the setpoint for acid or alkaline dosage, the tolerance of the setpoint before an alarm is activated, the dosage mode: automatic, continuous on or OFF and the over dosage control by setting the overtime dosage knob.
  • Hanna’s exclusive Fail Safe Alarm System protects against risks typical of industrial environments
  • Temperature compensation ensures fast, accurately compensated readings
  • Backlit, LCD display for easy viewing
Inquire Now

PEI Body Reference Electrode for FC301B - HI5313

503 AED
The HI5313 is a PEI body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 60℃.This design consideration is made for use with the FC301B fluoride half-cell ion selective electrode.
  • Half-Cell Design
  • Durable PEI Body
  • Gel Electrolyte
Inquire Now

Panel-mounted ORP Digital Controller - mV600

The mV600 controllers have been engineered with a number of outstanding features to meet all of your process control needs. mV600 offer a multitude of possibilities from ON/OFF or proportional dosage to analog recorder output and alarm. A host of self-testing features and user-friendly functions make mV600 a great value.
  • Accurate, reliable and simple to install.
  • Fully programmable microprocessor memory.
  • Wiring the controllers is simple with extractable terminal modules
Inquire Now

Panel-mounted pH Analog Indicator with Self Diagnostic Test – HI8510

1,831 AED
HI8510 is ideal for monitoring pH in process control. It provides highly accurate pH measurements and displays values on an easy-to-read LCD. BNC input, amplified probe input and input from transmitter are supported.
  • Automatic temperature compensation ensures fast, accurately compensated readings
  • Displays values on the easy to read LCD
  • A removable, transparent splash-proof cover protects the front panel
  • ±5V power output and input terminals for amplified electrodes
Inquire Now

ORP Mini Controller with Analog Output - BL932700-12VDC

910 AED
The BL932700 is a compact, ORP process controller designed for applications where space or cost is important. The device may be used with any ORP electrode with a standard BNC connector. It’s adjustable dosing relay may be configured to dose above or below a user programmable mV setpoint. Users may choose from automatic or manual dosing modes allowing for easy maintenance and troubleshooting. Large Clear LCD A large LCD clearly displays the parameter you are monitoring. Fire Retardant Casing Special materials provide additional protection in the event of an emergency. BNC Connection The controller features a BNC connector that allows any ORP probe with a BNC connector to be used.
Inquire Now

Glass Body Reference Electrode for Measurements with Remote Filling - HI5314

703 AED
The HI5314 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a double ceramic junction in the outer reference cell and a side arm construction.This design consideration is made for use in applications that require remote filling in temperatures ranging from -5 to 100℃.
  • Refillable Electrode
  • Double Ceramic Junction
  • Side Arm Construction
Back to Top
img
Product has been added to your cart