Out of stock

DiST 4 Waterproof EC Tester (0.00-20.00 mS/cm) – HI98304

The Hanna Instruments HI98304 DiST 4 is a high-range electrolytic conductivity (EC) tester that can measure up to 20.00 mS/cm making it ideal for a variety of applications including water treatment, boilers and cooling towers, agricultural including hydroponics, and general laboratory use. The DiST 4 is a rugged and reliable pocket-sized tester for use in the lab or field. This modern looking meter is only 0.7″ thick and extremely ergonomic, fitting comfortably in your hand. This tester keeps things simple with a two-button operation; one for ON/OFF, the other for calibration.

  • Large Multi-level LCD
  • Exposed Temperature Probe for Fast Response
  • Simple Two-Button Operation

204 AED

Estimated delivery: 6 - 7 December

Inquire Now
SKU:HI98304

The DiST 4 features a large multi-level LCD which displays both conductivity and temperature readings simultaneously. The EC readings are displayed with a 0.01 mS/cm resolution and with an accuracy of ±2% full scale. The EC range of the HI98304 is from 0.00 to 20.00 mS/cm. An exposed temperature sensor allows for rapid automatic temperature compensated conductivity measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

Conductivity readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Calibration is performed by pressing the dedicated calibration button. Once in calibration mode submerge the probe in 12.88 mS/cm calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.

Setup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.

Overview

HI98304 DiST 4 multi-level LCD

Multi-Level LCD
The large LCD displays EC, temperature, calibration tag, battery level and instability indicator.

HI98304 DiST 4 Exposed Temperature Probe

Exposed Temperature Probe
An exposed temperature probe allows for an extremely fast and stable EC measurement.

HI98304 DiST 4 Two Button Operation

Two-Button Operation
Only two buttons for meter operation. One for on/off and one for calibration.

Features/Benefits:

Slim, Ergonomic Design

  • With rounded edges and a case that is only 17 mm (0.7”) thick, the HI98304 is thin and fits comfortably in the hand or pocket.

Large Multi-level LCD

  • The LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both the pH and temperature simultaneously.

Two-button Operation

  • One for ON/OFF, the other for calibration.

Exposed Temperature Sensor

  • Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either ℃ or ℉.

Graphite Sensor

  • Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.

Automatic Calibration

  • Automatic calibration at 12.88 mS/cm with a single push of a button.

Stability Indicator

  • A clock tag stability indicator will disappear to alert the user when the reading is stable.

Automatic Shut-off

  • User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.

Low Battery Indicator

  • Low battery indicator that is displayed when less than 10% battery life is remaining.

Battery % Level at Startup

  • At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.

Specifications

SKU HI98304
Name DiST 4 Waterproof EC Tester (0.00-20.00 mS/cm) – HI98304
EC Range 0.00 to 20.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% F.S.
EC Calibration automatic, one point at 12.88 mS/cm
EC/TDS Temperature Compensation automatic from 0.0 to 50.0°C (32.0 to 122.0°F)
Temperature Correction Coefficient 1.9%/°C
Temperature Range 0.0 to 50.0°C (32.0 to 122.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.5°C (±1°F)
Automatic Shut-Off 8 minutes, 60 minutes, or disabled
Battery Type/Life CR2032 3V Li-Ion (1 pc.) / approximately 250 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH 100%
Dimensions 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
Weight 68 g (2.4 oz.) without battery

Ordering Info

HI98304 is supplied with protective cap, 12.88 mS/cm calibration solution sachet (4), CR2032 battery, instrument quality certificate and instructional manual.

Manuals

DiST 4 Waterproof EC Tester (0.00-20.00 mS/cm) – HI98304

Bestsellers

Inquire Now

Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301

481 AED
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction. The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
  • Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
  • Double Junction Reference
  • 3.5 mm Connector

pH/EC/TDS Multiparameter Probe for use with HI9814 - HI1285-7

463 AED
The HI1285-7 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI1285-7 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, and other agricultural applications. The HI1285-7 is designed for use with Hanna’s HI9814 portable multiparameter meter.
  • Pre-amplified pH Electrode
  • Amperometric EC/TDS Sensor
  • CAL Check Compatible

Foodcare pH Electrode for Semi-Solid with Quick Connect DIN Connector - FC2023

743 AED
The FC2023 is an amplified double junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190. The FC2023 electrode features a food grade plastic PVDF body, an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape. This design consideration is ideal for pH measurements in dairy products, emulsions, cream, or other semi-solid samples. The recommended operating temperature range is from 0 to 50℃.
  • Low Temperature Glass
  • PVDF Body
  • Open Junction

pH/EC/TDS Multiparameter Probe - HI1285-51

463 AED
The HI1285-51 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilizes two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples.The design consideration for the HI1285-51 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-51 is designed for use with Hanna’s HI9813-51, HI9812-51, and HI9811-51 portable multiparameter meters.
  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131

663 AED
The HI98131 is a slim, lightweight, and waterproof pocket sized meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature. The meter operation is simplified with two buttons. One is used for on/off and for calibration while the other is used to switch between the measurement modes. The HI98131 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
  • 3 parameters, pH, EC/TDS and temperature, in one meter
  • Quick Cal Mode to calibrate pH and EC/TDS with one solution
  • TDS Conversion Factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)

HI7004L pH 4.01 Calibration Solution (500 mL)

55 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
Inquire Now

edge® Wine pH Meter (kit) - HI2020W

edge® digital pH meter for wine kit delivers precision while offering simplicity and versatility in a sleek design. Upgrade to the Hanna edge® wine pH kit for professional winemakers. The HI2020W allows you to add a conductivity probe and a dissolved oxygen probe to give you full versatility. Fast results, ultra-accurate, hassle-free analysis.
  • Complete meter kit for measuring pH in wine.
  • CAL Check™ feature ensures the accuracy of the meter.
  • Great for professional and home winemakers.
Back to Top
Whatsapp