Dissolved Oxygen Controller with Extended Range and Analog Output – HI8410

The HI8410 is a panel mounted dissolved oxygen controller that is used to maintain and monitor the concentration of DO in a wide range of industrial process applications. The HI8410 uses a Galvanic probe that typically requires less maintenance than a Polarographic style making it ideal for long term monitoring.

  • Fail Safe Alarm System protects these meters against the pitfalls of process control.
  • Low maintenance Galvanic probe.

2,728.00 AED

Estimated delivery: 23 - 24 June

SKU:HI8410

HI 8410 is a panel-mounted DO controller designed for simplicity of use in a wide range of industrial process applications. Dissolved Oxygen is indicated in mg/L (ppm) or in % of saturation in accordance with the selection switch on the back panel. The temperature can be measured in the range from -5 to 50 ā„ƒ. The Dissolved Oxygen readings are automatically compensated for the temperature effects on the oxygen solubility and membrane permeability. Moreover, the salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters.

The instruments are designed with a standard DIN panel mount with membrane keypads and large LCD with backlight on the front, and provide a series of auto-diagnostic functions. Probes, power supply, contacts and recorders are connected on the rear panel through screw terminals.

The DO probe is provided with a membrane covering the galvanic sensor and a built-in thermistor for temperature measurement and compensation.
The Oxygen that passes through the membrane causes an electric current flow, from which the oxygen concentration is determined. Other features include: recorder output in 0-20 mA or 4-20 mA configuration; LED indicators which identify whether the controller is in operation mode or setup selection mode; overtime control function; hysteresis setting. The instrument is supplied with a plastic front cover and two mounting brackets. Power cables are not included.

HI8410 FEATURES/BENEFITS:

Fail Safe Alarm System

  • Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Automatic Temperature Compensation

  • The Dissolved Oxygen readings are automatically compensated for the temperature effects on the oxygen solubility and membrane permeability

Salinty Compensation

  • The salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters.

Simple to Use

  • The instruments are designed with a standard DIN panel mount with membrane keypads and large LCD with backlight on the front, and provide a series of auto-diagnostic functions.

Analog Output

  • To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.

Diagnostic Tests

  • The HI 8410 controllers are designed with built-in diagnostic functions to enable the user to check and troubleshoot the instrument. The checks performed are through the front panel keys and can be used to isolate the cause of malfunction.

Specifications

SKU HI8410
Name Dissolved Oxygen Controller with Extended Range and Analog Output – HI8410
Dissolved Oxygen Measurement Type galvanic: HI76410/4 with 4 m (13.1’) cable or HI76410/10 with 10 m (32.8’) cable (not included)
Dissolved Oxygen Range 0.0 to 50.0 mg/L (ppm) Oā‚‚; 0 to 600 % O
Dissolved Oxygen Resolution 0.1 mg/L (ppm) or 1% (Oā‚‚)
Dissolved Oxygen Accuracy ±1% of reading (Oā‚‚)
Dissolved Oxygen Calibration Manual, one point, in saturated air
Dissolved Oxygen Temperature Compensation Automatic, from -5 to 50 °C (23 to 122 °F)
Salinity Compensation 0 to 51 g/L (resolution 1 g/L)
Dissolved Oxygen Dosing Relay 1, isolated, 2A, max. 240V, resistive load, 1,000,000 strokes
Dissolved Oxygen Dosing Set Point 5 to 600 % O2 0.5 to 50.0 mg/L (ppm) O2
Dissolved Oxygen Hysteresis Band 0.5 to 2.4 mg/L (ppm) O2
Dosing Control OFF/AUTO/ON with selection switch
Alarm Relay Range 1.0 to 5.0 mg/L (ppm) Oā‚‚
Over Dosing Control Adjustable, from 5 min to 60 min with knob or Disable by wire strap – on real panel
Backlight Continuous ON
Enclosure Black anodized aluminum body; front and back with ABS; transparent splash-proof front cover
Panel Cutout 141 x 69 mm (5.6 x 2.7”)
DO Probe HI 76410/4 with 4 m cable or HI 76410/10 with 10 m cable
Analog Output 0 to 20 mA or 4 to 20 mA (isolated)
Power Supply 115 or 230 Vac; ± 10% (user selectable); 60/50 Hz
Environment -10 to 50 °C (14 to 122 °F); RH 95%
Weight 1 kg (2.2 lb.)

Ordering Info

The HI8410 is supplied with mounting brackets and instructions. Probes (not included): HI76410/4: Galvanic DO probe (fixed) with internal temperature sensor, DIN connector and 4 m (13.1’) cable HI76410/10: Galvanic DO probe (fixed) with internal temperature sensor, DIN connector and 10 m (32.8’) cable

Manuals

Dissolved Oxygen Controller with Extended Range and Analog Output – HI8410

Bestsellers

Inquire Now

COD Medium Range Reagent Vials, EPA Method (25 tests) - HI93754B-25

250.00 AED
The HI93754B-25 are reagent vials that follow the EPA approved method for the medium range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    COD High Range Reagent Vials, Dichromate Method (25 tests) - HI93754C-25

    250.00 AED
    The HI93754C-25 are reagent vials that follow the dichromate method for the high range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    COD Medium Range Reagent Vials, ISO Method (25 tests) - HI93754G-25

    250.00 AED
    The HI93754G-25 are reagent vials that follow the ISO approved method for the medium range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.
    Inquire Now

    AmpHelĀ® Flat-tip pH Electrode - High Temperature, 5m Cable

    1,104.00 AED
    This amplified pH electrode is designed for high temperature industrial applications with features such as a PTFE junction, Pt100 temperature sensor, and PVDF body. With it's durable design, you can count on this electrode to stand up to your process environment.
    • Flat-tip pH electrode.
    • High temperature glass can stand up to the effects of elevated temperatures leading to longer probe life.
    • Built for everyday, demanding use in industrial applications.
    Inquire Now

    In-line Conductivity Probe with Pt100 Sensor, 3m Cable - HI7639

    HI7639 is In-Line Conductivity probe for conductivity measurement in various industrial applications. This probe has inbuilt pt100 temperature sensor for automatic temperature compensation. This probe is based on four ring technology and it is made up of platinum rings.
    • Four-ring probes measure conductivity with platinum sensors.
    • Built-in temperature sensor for Automatic Temperature Compensation.
    • PEI body
    Inquire Now

    Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps, Analog Outputs and In-line Mounting Kit

    6,237.00 AED
    Control with Confidence The BL123 Swimming Pool Controller is a complete system designed for maintaining swimming pool, hot tub, and spa disinfection water quality. The BL123 is available in two configurations. The basic version is the in-line model which allows for direct installation of probe and chemical injection fittings into existing piping. The other version is a panel mounted version with a bypass flow cell. The bypass flow cell allows for calibration and maintenance of the probe without having to shut down the recirculation pump. Additional features of the BL123 include LED indicators for dosing, meter status and service, real-time graph display, programmable alarms, and password protection.

    Panel-mounted ORP Analog Indicator with Self Diagnostic Test – HI8512

    1,942.00 AED
    HI8512 ORP panel mounted controller is ideal for process control monitoring in a wide range of industrial applications. This instrument has been designed for easy and fast installation, and is provided with membrane keypads on the front panel, large display, and auto-diagnostic functions.
    • Auto-diagnostic tests for electrode and instrument status.
    • Displays values on the easy to read LCD.
    • A removable, transparent splash-proof cover protects the front panel.
    Back to Top
    Whatsapp
    Product has been added to your cart