Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103

The HI764103 is a digital dissolved oxygen probe with a built-in temperature sensor. This galvanic probe contains a built-in microchip that stores sensor type, serial number, and calibration information that is automatically detected by the HI98199 portable meter. The sensor features a silver cathode with a zinc anode, an integrated temperature sensor, and easily replaceable HDPE membrane caps.

  • Digital Probe
  • Galvanic Technology
  • Replaceable pre-tensioned HDPE Membrane

1,297.00 AED

Inquire Now
SKU:HI764103
digital electrode

Built-in Microchip

The built-in microchip stores sensor type, serial number and calibration information including date, time, and calibration points. This information is automatically retrieved by HI98199 once the probe is plugged in. The ability to transfer information allows for hot swapping of probes without recalibrating. All DO measurements are performed within the probe and transferred digitally to the meter.

 Galvanic Technology

Galvanic Technology

The galvanic technology is a passive from of measurement is that the probe generates a voltage spontaneously based on the dissolved oxygen concentration that passes through the membrane and reacts with the fill solution. There is no warm up time with galvanic probes since the reaction is taken place continuously.

Replaceable Membranes

Replaceable Membranes

With screw-on caps, the DO HDPE membrane is easy to replace for faster maintenance.

Replaceable DO membrane caps

Built-in Temperature Sensor

DO measurements are automatically compensated for temperature changes

Replaceable DO membrane caps

Quick Connect Din Connector

With screw-on caps, the DO HDPE membrane is easy to replace for faster maintenance.

Specifications

SKU HI764103
Name Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103
Body Material ABS
Temperature Sensor built-in
Cable 4 meter (13.3 in.)
Connector Type quick connect DIN
Recommended Use wastewater, water, aquaculture, beverage
Notes to only be used with HI98199

Manuals

Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7007L pH 7.01 Calibration Solution (500 mL)

61.00 AED
HI7007L is a premium quality pH 7.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
Back to Top
Whatsapp
Product has been added to your cart