The HI96714 portable photometer is for the measurement of cyanide. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Checkā„¢ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Checkā„¢ – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.

GLP – Records the date of the last user calibration performed.

Built in timer – Allows the use of a timer to ensure the appropriate 3 minutes and 30 seconds reaction time is used for the chemical reaction. At the end of the timer countdown the meter will automatically take the reading. This feature ensures consistency across multiple users.

Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.

Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator

    The instrument has a battery level indicator to display reaming life as follows:

  • 3 lines for 100 % capacity</li
  • 2 lines for 66 % capacity</li
  • 1 line for 33 % capacity</li
  • Battery icon blinks when the capacity is less than 10%.

Units of measure – Appropriate unit of measure is displayed along with reading.

optical system

The term ā€œcyanideā€ refers to all of the CN groups in cyanide compounds that can be determined as the cyanide ion, CN. Originating in water primarily from metallurgical and galvanic industrial plants, cyanide is highly toxic to the human nervous system.

The HI96714 uses an adaptation of the Pyridine-Pyrazolone method per the Standard Methods for the Examination of Water and Wastewater to measure cyanide concentrations of less than 0.200 mg/L (ppm). When the pyridine-based reagent is added to samples containing cyanide, the sample will turn a blue hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For cyanide determination, a narrow band interference filter at 610 nm (orange) allows only orange light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

cal check standards

CAL Checkā„¢ standards with certificate

The HI96714-11 CAL Checkā„¢ standards are used for calibration and performance verification of photometers with the CAL Checkā„¢ function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 ā„ƒ
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage
photometer steps

Specifications

SKU HI96714
Name Cyanide Portable Photometer – HI96714
Cyanide Range 0.000 to 0.200 mg/L
Cyanide Resolution 0.001 mg/L
Cyanide Accuracy ±0.005 mg/L ±3% of reading @ 25°C
Cyanide Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Pyridine-Pyrazalone method. The reaction between cyanide and reagents causes a blue tint in the sample.
Photometer/Colorimeter Light Source Tungsten Lamp
Photometer/Colorimeter Light Detector Silicon Photocell with narrow band interference filter @ 610 nm
Battery Type/Life 9V battery
Automatic Shut-Off After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 360g (12.7oz.)
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)

Ordering Info

HI96714 is supplied with two sample cuvettes with caps, 9V battery, instrument quality certificate, and instruction manual. *CAL Check™ standards and testing reagents sold separately.

Manuals

Cyanide Portable Photometer – HI96714

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

61.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality
Back to Top
Whatsapp
Product has been added to your cart