In stock

COD Ultra-High Range Reagent Vials, EPA Method (25 tests) – HI93754J-25

The HI93754J-25 are reagent vials that follow the EPA approved method for the ultra-high range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high-quality reagents are clearly marked with the lot number and expiration date on each box for traceability.

  • Bar coded vials
  • Pre-dosed reagents for ease of use
  • Marked with expiration date and lot number for traceability

236 AED

Estimated delivery: 20 - 21 September

SKU:HI93754J-25

The HI93754J-25 COD kit contains 25 ready-to-use vials containing pre-measured reagents. These high-quality reagents follow the EPA approved method 410.4. In this method, a heated digestion is required to oxidize organic matter in the sample.

Hanna vials contain approximately 3 mL of pre-dosed reagent so the user only needs to add a small quantity of the sample. With pre-dosed vials, test preparation time is dramatically reduced since there is no reagent preparation procedure. The vials and caps of the COD reagents have been designed to avoid accidental reagent spills.

Mercury-free – For those who do not wish to handle mercury reagents, our “green, ” mercury-free reagents are available for COD determination. These reagents are more sensitive to chloride interferences, as mercuric sulfate is not present. While the mercury-free reagents are easier to dispose of, they may be unacceptable for reporting purposes.

ISO – The ISO approved method 15705 for COD determination also requires the use of mercuric sulfate (HgSO4) to reduce the interference of chloride. Containing similar chemical reagents as the EPA method, it is important to treat used ISO vials as hazardous waste, as mercury waste requires recycling.

Method

Parameter

Range (as O2)

Resolution

Accuracy

Reagent Code

EPA

COD LR

0 to 150 mg/L

1 mg/L

±5 mg/L ±5% of reading

HI93754A-25

COD MR

0 to 1500 mg/L

1 mg/L

±15 mg/L ±4% of reading

HI93754B-25

COD UHR

0.0 to 60.0 g/L

   

HI93754J-25

Dichromate

COD HR

0 to 15000 mg/L

10 mg/L

±150 mg/L ±3% of reading

HI93754C-25

Mercury-free

COD LR

0 to 150 mg/L

1 mg/L

±5 mg/L ±5% of reading

HI93754D-25

COD MR

0 to 1500 mg/L

1 mg/L

±15 mg/L ±4% of reading

HI93754E-25

ISO

COD LR

0 to 150 mg/L

1 mg/L

±5 mg/L ±5% of reading

HI93754F-25

COD MR

0 to 1500 mg/L

1 mg/L

±15 mg/L ±4% of reading

HI93754G-25

Specifications

SKU HI93754J-25
Name COD Ultra-High Range Reagent Vials, EPA Method (25 tests) – HI93754J-25
Package 16 mm vials
Quantity 25 tests
Method dichromate EPA

Manuals

COD Ultra-High Range Reagent Vials, EPA Method (25 tests) – HI93754J-25

Bestsellers

Hydrochloric Acid 0.1N, 1L - HI70463

81 AED
HI70463 is a hydrochloric acid titrant for use in standard acid-base titrations. Hanna titration solutions and reagents have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Air-Tight
  • Acid-Base Reagent
  • Tamper-Proof Seal
Inquire Now

Ammonia Test Kit for Fresh Water Replacement Reagents (25 tests) - HI3824-025

101 AED
The HI3824-025 are replacement reagents for the colorimetric determination of ammonia (as NH3-N) with the HI3824 Ammonia Test Kit for Fresh Water. There are enough reagents for approximately 25 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

COD Medium Range Reagent Vials with Barcode, EPA Method (25 tests) - HI94754B-25

227 AED
The HI94754B-25 are barcode reagent vials that follow the EPA approved method for the medium range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Barcoded vials
  • Marked with expiration date and lot number for traceability
Inquire Now

Acid Reagent for Total Sulfur Dioxide - HI84100-52

80 AED
The HI84100-52 is a 500 mL bottle of acid reagent required for determination of total sulfur dioxide in wine using the HI84100 Sulfur Dioxide Mini Titrator for Wine Analysis.*This acid reagent is used to lower the pH value of the sample prior to performing a titration. With 5 mL of reagent required per test, there is enough acid reagent for 100 tests.*The HI84100 Sulfur Dioxide Mini Titrator has been discontinued. The new version is the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis which has its own set of reagents.
  • Pre-measured solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

Phosphate HR Reagents (300 tests) - HI93717-03

349 AED
The HI93717-03 are reagents for the colorimetric determination of phosphate. There are enough reagents for 300 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle and packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

Phenylarsine Oxide (PAO) Solution (0.00564N), 500 mL - HI70466

237 AED
HI70466 is a phenylarsine oxide (PAO) solution for the use in amperometric titrations for the determination of chlorine in aqueous solutions. Hanna titration solutions and reagents have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Air Tight
  • Amperometric Reagent
  • Tamper-Proof Seal
Inquire Now

Dissolved Oxygen Reagents (100 tests) - HI93732-01

294 AED
The HI93732-01 are reagents for the colorimetric determination of dissolved oxygen (DO). There are enough reagents for 100 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Back to Top
Whatsapp
Product has been added to your cart