Out of stock

Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps with Panel Mounted Flow Cell Kit

Control with Confidence

The BL122 Swimming Pool Controller is a complete system designed for maintaining swimming pool, hot tub, and spa disinfection water quality. The BL122 is available in two configurations. The basic version is the in-line model which allows for direct installation of probe and chemical injection fittings into existing piping. The other version is a panel mounted version with a bypass flow cell. The bypass flow cell allows for calibration and maintenance of the probe without having to shut down the recirculation pump. Additional features of the BL122 include LED indicators for dosing, meter status and service, real-time graph display, programmable alarms, and password protection.

7,319.00 AED

Inquire Now
SKU:BL122-20

Controller Overview

HI902C Angled

Multiple Configurations

The controller is available in one of
two configurations: an in-line model which allows for direct
installation of the probe and chemical injection fittings into existing
piping (BL120-10) or a panel mounted system with a bypass flow cell (BL120-20). The bypass
flow cell allows for calibration and maintenance of the probe without
having to stop the recirculation pump.

BL120 410 FlowCell

Digital Combination Probe

The HI1036-1802 is a digital probe that
measures pH, ORP, and temperature. This probe also incorporates a
potential matching pin. The pin is considered the ?earth ground?
connection and is used to prevent ground loop effects from causing
erratic readings and damage to the system.

HI1036 18 angle

Dosing & Control

BL121 cords

Peristaltic Dosing System

The BL122 is equipped with two peristaltic dosing pumps with
replaceable chemical resistant tubing. When using a diaphragm pump,
chlorine gas formed from outgassing can collect in the pump head
resulting in the pump losing its prime; the buildup of chlorine gas is
not a problem with peristaltic pumps that use rollers and tubing.

Proportional Pump Control

The BL122 features proportionally controlled dosing pumps. Based on
the sensitivity of the process to chemical addition, these controllers
allow the user to adjust a proportional band. This setting determines
the amount of time that the pumps are dosing as a percentage of the
deviation from the set point allowing for very fine control in
maintaining the desired set point.

Adjustable Flow Rate

The flow rate from the dosing pumps is adjustable from 0.5 to
3.5L/h. Larger bodies of water require more chemical to be dosed than
small bodies since it takes more chemical to realize a change in the
reading. The adjustable flow rate, like the proportional band, allows
for better control in maintaining a desired set point.

ORP Dosing Consent

With chlorine disinfection there is an inverse relationship between
pH and ORP. As the pH level increases, the ORP level decreases. The
BL122 utilizes a dosing consent feature that will not dose chlorine
until the pH value is first corrected since it is possible to have a
low ORP value even though there is sufficient chlorine. The dosing
consent feature prevents wastage of chemicals and avoids a higher than
necessary chlorine concentration.

Connections & Display

BL121 Display
BL121 Display

Circulation Pump Monitoring

An inline flow switch or a
mechanical relay connected to the recirculation pump power source
may be connected to the hold input of the BL122. With no flow or
when no power is applied to the recirculation pump, the hold
circuit disables the dosing pumps. This will prevent any dosing of
chemical when there is no movement of water in the system.

Multifaceted Display

The versatile display of the BL121
allows for three screen modes. The LCD can display all three
parameters at one time, a 3-second cycle of single parameters, or a
real-time plot screen with options for parameter selection,
zooming, and log recall.

Programmable Alarm System

Hanna controllers allow users to
enable or disable the low and high level of alarms for all
parameters. When an alarm is activated, all dosing will stop.
The alarm system also offers overdosing protection if the value
is not corrected within a specified time interval then the
meter will go into alarm status.

Multicolored LED Indicators

The BL122 offers multiple LED
indicators for status, servicing, and pump operation. The
STATUS LED changes color based on operational state; green when
setting are in range, yellow when user intervention is
required, and red for problems. The SERVICE LED indicates any
alarms and process errors experienced by the controller.

Communication & Security

BL121 USB

Automatic Logging

The readings for each parameter are automatically logged every
10 seconds. A new log is started each time the instrument is
calibrated or at the start of a new day. Logged data include pH,
ORP, and temperature values, last calibration data, setup
configuration, and any event data. Each log is saved as a .csv file
for easy transfer.

USB Connectivity

For review and storage the users can easily transfer data to a
PC using a flash drive and the USB port.

Password Protection

Hanna?s BL122 controller features a password protection solution
that offers restricted access to calibration, setup, and review of
logged data. The password can be set and enabled/disabled during
general setup of the instrument.

Specifications

SKU BL122-20
Name Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps with Panel Mounted Flow Cell Kit
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.05 pH
pH Calibration pH buffer calibration: Automatic, two points (4.01, 7.01, 10.01 pH)pH process calibration: Single point, adjustable
pH Temperature Compensation Automatic -5.0 to 105.0 ĀŗC (23.0 to 221.0 ĀŗF)
ORP Range ±2000 mV
ORP Resolution 1 mV
ORP Accuracy ±5 mV
Temperature Range -5.0 to 105.0 ºC (23.0 to 221.0 °F)
Temperature Resolution 0.1 °C (0.1 ºF)
Temperature Accuracy ±1 ºC (±1.8 ºF)
Dosing Control Proportional feed using adjustable set point and adjustable proportional band.Delay to start at power-on and overdosing protection using.Over feed safety timer.
Consent Relay pH dosing interlocked with ORP
Alarm Relay Set Point High and Low with enable/disable option for all parameters.Alarm is triggered for 5 consecutive readings over/under threshold.
Over Dosing Control Over feed safety timer.
Analog Ouput Signal (BL122 only – 3) 4 to 20 mA, sourcing, configurableOutput impedance ≤ 500 Ohm Accuracy < 0.5 % FSGalvanically isolated up to 50 V relative to earth
Digital Input Signal Galvanic isolated, powered contact typeLow level in acid/base tank (contact open)Low level in chlorine tank (contact open)Hold input (contact open)
Power Consumption 10 VA
Multi-parameter Probe HI1036-18XX (02, 05, 10, 15, 20 m of cable) pH/ORP/Temperature with matching pin combined digital probe
Logging Type Automatic Log of measurements (pH, ORP, Temperature) and events: alarms, errors, power-failed
Logging Memory 60 days logging with 10 s period (or 100 logs)
Connectivity USB
GLP pH/ORP
Power Supply 100 – 240 VAC
Environment 0-50 ĀŗC (32-122 ĀŗF) Max 95% RH non-condensing
Dimensions 245 x 188 x 55 mm (73 mm with pumps)9.6 x 7.4 x 2.2ā€ (2.9ā€ with pumps)
Weight 1700 g (60 oz)

Manuals

Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps with Panel Mounted Flow Cell Kit

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7030L 12880 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7030L is a premium quality 12, 880 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal
Back to Top
Whatsapp
Product has been added to your cart