Chromium, Hexavalent High Range Portable Photometer – HI96723

The HI96723 is no longer available.

Below is the link to a new meter that has been upgraded with many advanced features including an improved optical system, dot matrix LCD that offers a graphical tutorial mode to help the user through the measurement process and is waterproof including the cuvette assembly.

Both meters use the same reagents.

view new meter

850.00 AED

Inquire Now
SKU:HI96723

The HI96723 portable photometer is for the measurement of chromium VI. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Checkā„¢ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Checkā„¢ – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.

GLP – Records the date of the last user calibration performed.

Built in timer – Allows the use of a timer to ensure the appropriate 3 minutes and 30 seconds reaction time is used for the chemical reaction. At the end of the timer countdown the meter will automatically take the reading. This feature ensures consistency across multiple users.

Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.

Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator – The instrument has a battery level indicator to display reaming life as follows:

  • • 3 lines for 100 % capacity
  • • 2 lines for 66 % capacity
  • • 1 line for 33 % capacity
  • • Battery icon blinks when the capacity is less than 10 %.

Units of measure – Appropriate unit of measure is displayed along with reading.

optical system

Hexavalent chromium salts are used in various industrial applications, such as in the manufacture of paints, dyes, explosives, and ceramics, and extensively in the metal finishing and plating industries. Due to its toxicity to humans, animals, and aquatic life, hexavalent chromium is actively monitored and neutralized in wastewater from the above industries.

The HI96723 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, diphenylcarbohydrazide method to measure chromium VI concentrations of less than 1000 µg/L (ppb). When the diphenylcarbohydrazide reagent is added to samples containing chromium VI, the sample will turn a purple hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For higher levels of chromium VI, a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

cal check standards

CAL Checkā„¢ standards with certificate

The HI96723-11 CAL Checkā„¢ standards are used for calibration and performance verification of photometers with the CAL Checkā„¢ function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 ā„ƒ
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage
photometer steps

Specifications

SKU HI96723
Name Chromium, Hexavalent High Range Portable Photometer – HI96723
Chromium, Hexavalent Range 0.00 to 1000 µg/L
Chromium, Hexavalent Resolution 1 µg/L
Chromium, Hexavalent Accuracy ±5 µg/L ±4% of reading @ 25°C
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, diphenylcarbohydrazide method. The reac- tion between chromium and the reagent causes a purple tint in the sample.
Photometer/Colorimeter Light Source Tungsten lamp
Photometer/Colorimeter Light Detector Silicon Photocell with narrow band interference filter @ 525 nm
Display Liquid Crystal Display (LCD)
Battery Type/Life 9V battery
Automatic Shut-Off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 360 g (12.7 oz.)
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)

Ordering Info

HI96723 is supplied with two sample cuvettes with caps, 9V battery, instrument quality certificate, and instruction manual. *CAL Check™ standards and testing reagents sold separately.

Manuals

Chromium, Hexavalent High Range Portable Photometer – HI96723

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart