Out of stock

Checktemp® 4 Folding Thermometer – HI151

The HI151 Checktemp® 4 is a folding thermistor thermometer that can measure temperature up to 300 ℃ (572 ℉). These thermometers offer many advanced features including CAL-Check for an internal verification of the electronics and a motion sensor which eliminates the need of closing and reopening the probe when the meter enters a power saving mode. The Checktemp 4 is available in six different colors which can be assigned to different products to avoid cross contamination in the restaurant, kitchen or production facility.

  • CAL Check to verify meter performance
  • Waterproof to IP67 Standards
  • Wake on motion

Inquire Now
SKU:HI151-
HI151 Checktemp 4 Temperature Tester

Ergonomic Design with Rubberized Grip

Checktemp® 4 has an ergonomic design that fits comfortably in the hand. The meter uses vulcanized rubber that is available in 6 different colors for a non-slip grip.

Waterproof Durable Casing

The Checktemp thermometer is completely waterproof to IP67 standards. The IP67 standard is for continuous immersion in water up to 1 meter (3′) in depth. The meters will actually float if accidentally dropped into a pot, vat or any other container.

Penetration Probe

The sharp, AISI 316 stainless steel probe is ideal for testing fresh, cooked and semi frozen food. The NTC thermistor is located in the sensing tip and allows for the measurement of food that is 2 cm (0.79″) thick.

HI151 Checktemp 4 Temperature Tester

Instrument Quality Certificate for Traceability

HI151 is calibrated to five points (-20.0, 0.0, 25.0, 60.0 and 120.0 ℃) and tested at three points using reference meters, the accuracy of which is traceable to NIST in the USA or an internationally acceptable national physical standards. Each meter is serialized and supplied with an instrument quality certificate

CAL-Check

With all thermometers there is drift in the electronics over time. Every time the thermometer is switched ON the LCD will display “CAL” then “-0-”, indicating that the factory calibration has been verified and the thermometer is ready for use.

Wake on Motion Sensor

The meter has an adjustable power save mode that can be disabled. The power save mode can be programmed to turn the display off and conserve power after 1, 2, 8, or 60 minutes. The built-in motion sensor detects when the meter is picked up and automatically turns the display back on.

Checktemp®4 Temperature Tester – HI151

HI151 Checktemp®4 Temperature Tester Family

Specifications

SKU HI151-web
Name Checktemp® 4 Folding Thermometer – HI151
Thermistor Temperature Range -50.0 to 300 °C / -58.0 to 572 °F
Thermistor Temperature Resolution 0.1 °C (-50.0 to 199.9 °C); 1 °C (200 to 300 °C)
0.1 °F (-58.0 to 199.9 °F); 1 °F (200 to 572 °F)
Thermistor Temperature Accuracy ± 0.2 °C (-30.0 to 170.0 °C); ± 0.4 °C (-50.0 to -30.0 °C and 170.0 to 199.9 °C); ± 1 °C (200 to 300 °C) ± 1 digit
±0.4 °F (-22.0 to 199.9 °F); ±0.8 °F (-58.0 to -22.0 °F);
±1 °F (200 to 392 °F); ±2 °F (392 to 572 °F) ± 1 digit
Automatic Shut-Off power save settings: 1 min, 2 min (default), 8 min, 60 m in. or OFF
Battery Type/Life CR2032 3V x 2 pcs. / approx. 4000 hours of use
Environment -20.0 to 50.0 ºC (-4.0 to 122.0 ºF)
Dimensions 165 x 45 x 24 mm (6.5 x 1.8 x 0.9”)
Weight 85 g (3.0 oz)

Ordering Info

HI151 Checktemp 4 is supplied with batteries, quality certificate, and instruction manual.

Manuals

Checktemp® 4 Folding Thermometer – HI151

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number
Back to Top
Whatsapp
Product has been added to your cart