Out of stock

Burette Assembly, 10 mL – HI900110

The HI900110 is a 10 mL burette assembly for the HI901 or HI902C automatic titration systems. The assembly includes the 10 mL syringe, aspiration tubes, and dispensing tubes, complete with blue protection tubes, gaskets, and tube locks.

  • Rotating light block shield
  • Easy to install
  • Chemically resistant materials

3,457.00 AED

Inquire Now
SKU:HI900110

The HI900110 is a 10 mL burette assembly for the HI901 or HI902C Automatic Titration Systems.

Clip-Lock Burettes

Clip-Lockā„¢ Exchangeable Burette System

With Clip-Lockā„¢ Exchangeable Burette System, it only takes a few seconds to exchange the reagent or titrant burettes to perform a different titration. With conventional titrators, there is a risk of cross-contamination; this specialized system prevents cross-contamination by eliminating the need for purging, cleaning, and refilling the burettes.

Simply sliding out the burette and detaching the dispensing tubes from the overhead assembly allows for quick and easy burette exchange. Having several prepared burettes on hand will make the Hanna titration systems the fastest and most versatile on the market.

Light Block

Light Block Shield

For applications that require the use of light-sensitive solutions, the burette of the HI900110 features a light block shield that can be rotated in front of the exposed glass. This shield helps prevent degradation of the titrant or reagent being used, ensuring titrations remain accurate each time.

Once the HI900110 burette is connected to the dosing pump, the titrator automatically recognizes the burette volume. In addition to the 10 mL burette, Hanna offers 5 mL, 25 mL, and 50 mL burettes for a wide variety of applications. Each burette is made from chemically resistant material, ensuring users many years of trouble-free operation.

The HI900110 also comes with an aspiration and dispensing tube. The aspiration tube features a fitting to ensure the titrant or reagent is securely taken up into the burette. The dispensing tube features a fitting on one end and a tapered dispensing tip on the opposite end to ensure the titrant or reagent is accurately dosed into the sample beaker. A durable blue protection tube covers the clear tubing to prevent kinks and to protect light-sensitive solutions from degradation. The aspiration and dispensing tubes also come with a gasket and tube lock, and can easily be replaced on any of the Hanna burette syringes.

Specifications

SKU HI900110
Name Burette Assembly, 10 mL – HI900110
Notes For use with the HI901 and HI902C automatic titration systems

Manuals

Burette Assembly, 10 mL – HI900110

Bestsellers

Ammonia Checker®HC Reagents (25 Tests) - HI700-25

72.00 AED
The HI700-25 are the replacement reagents for the HI700 Ammonia Low-Range CheckerĀ® HC. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high-purity chemicals
  • Marked with expiration date and lot number for traceability

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

Original price was: 32.00 AED.Current price is: 31.00 AED.
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Back to Top