Benchtop pH Meter with 0.01 pH Resolution – HI2210

The HI2210 is a basic, affordable pH benchtop meter that features automatic calibration to 1 or 2 points with a choice of 5 preprogrammed buffers. All readings are automatically compensated for temperature variations from the supplied thermistor probe.

The meter has a large, easy-to-read LCD that displays pH and temperature simultaneously. The HI2210 is supplied complete with a pH electrode, temperature probe, calibration buffers, reference refill electrolyte, cleaning solutions, and a probe holder.

  • Large, Clear Display
  • Easy Navigation
  • Universal BNC Connection

1,544.00 AED

Inquire Now
SKU:HI2210-01

The HI2210 is a basic affordable pH benchtop meter. Operation is simplified to calibration, pH and temperature readout, and a last stored reading feature. To enter calibration mode the user simply presses the “CAL” button. The HI2210 can be calibrated to 1 or 2 points using the 5 pre programmed buffers (4.01, 6.86, 7.01, 9.18, and 10.01). Once a buffer is recognized and the reading is stable the meter will display “CFM” for confirm. The “CFM” key is pressed and the reading is stored.

The HI2210 has two separate inputs for a BNC pH electrode and thermistor temperature probe. The BNC connector is a universal connector that is commonly available and allows the user to select from a wide variety of pH electrodes for their particular application. The separate temperature probe provides for a high 0.5ā„ƒ accuracy measurement for precise temperature compensation.

Features at-a-glance

Simple User Interface – Operation is simple with limited features that only require the use of a couple of buttons. Readings are easy to view on the large, clear display.

One or Two-Point Calibration – Automatic calibration can be performed at 1 or 2 points using the 5 preprogrammed buffers (4.01, 6.86, 7.01, 9.18, and 10.01).

HI1131B pH Electrode – The HI2210 is supplied with the HI1131B glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction and HT glass design allows the HI1131B to be used in a wide variety of application from samples with metals and Tris buffer to samples at elevated temperatures.

Temperature Compensation – The HI2210 offers automatic or manual temperature compensation of pH measurements over a wide range from -9.9 to 120.0ā„ƒ.

Stability Indicator – The HI2210 features a stability indicator. An hourglass appears on the display when there is instability in the reading. The hourglass disappears once the reading has stabilized. At that time a reading should be taken or stored.

Measurement Recall – The HI2210 has a “MEM” button to store a reading. The reading can be recalled at anytime by pressing the memory recall “MR” button.

Specifications

SKU HI2210-01
Name Benchtop pH Meter with 0.01 pH Resolution – HI2210
pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.01 pH
pH Calibration automatic, one or two-point with five memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation automatic or manual from -9.9 to 120.0°C
pH Input impedence 10¹² Ohms
Temperature Range -9.9 to 120.0°C (14.2 to 248.0°F)
Temperature Resolution 0.1 °C
Temperature Accuracy ±0.5 °C (0.0 to100.0 °C); ±1 °C (outside)
pH Electrode HI1131B glass body pH electrode with BNC connector
Temperature Probe HI7662 stainless steel temperature probe
Analog Output 0 to 5 V according with: 0 to 14 pH or -1999 to +1999 mV; temperature always 0
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 240 x 182 x 74mm (9.4 x 7.1 x 2.9ā€)

Ordering Info

HI2210 is supplied with HI1131B pH electrode, HI7662 temperature probe, HI76404N electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7082 electrolyte solution, HI700601 cleaning solution sachet, 12 VDC adapter, and instructions.

Manuals

Benchtop pH Meter with 0.01 pH Resolution – HI2210

Bestsellers

HI7004/1L pH 4.01 Calibration Solution (1 L)

77.00 AED
HI7004/1L is a premium quality pH 4.01 calibration solution that has been dyed red for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

HI7010L pH 10.01 Calibration Solution (500 mL)

59.00 AED
HI7010L is a premium quality pH 10.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7004L pH 4.01 Calibration Solution (500 mL)

61.00 AED
HI7004L is a premium quality pH 4.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Color coded label for easy pH buffer value identification
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7031L is a premium quality 1, 413 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7007/1L pH 7.01 Calibration Solution (1 L)

77.00 AED
HI7007/1L is a premium quality pH 7.01 calibration solution that has been dyed green for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle
  • Air-tight Seal

Combo pH/Conductivity/TDS Tester (Low Range) - HI98129

634.00 AED
The HI98129 makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC/TDS (0 to 3999 µS/cm EC/ 0 to 2000 ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.
  • Waterproof
  • Replaceable pH electrode with extractable junction
  • Automatic calibration
Back to Top
Whatsapp
Product has been added to your cart