Autosampler for Potentiometric Titrator – HI922

The HI922 Autosampler is an automated titration sample handling system designed for use with the HI932 Automatic Titration System. This high quality system makes the titration of multiple samples quick and easy. The HI922 Autosampler interfaces directly with the HI932 to access titration methods, allowing up to 18 samples to be run consecutively.

The HI922 can utilize up to three peristaltic pumps for reagent addition, sample leveling, and waste aspiration. An included control panel allows for manual operation of the motors and pumps. The Autosampler also features a built-in magnetic stirrer or optional overhead stirrer, status indicator lights, USB interface with compatible barcode reader, and built-in RFID for each tray.

Inquire Now
SKU:HI922

Intuitive Automation

HI922 peristaltic pump

Chemically Resistant Pumps

You can connect up to three peristaltic pumps on the HI922 Autosampler. These peristaltic pumps use high performance plastic, engineered to be chemically resistant with a long service life. Each pump has a flow rate greater than 200 mL/min and can be used for reagent addition, sample leveling, or waste removal.

HI922 probe holder

Multipurpose Arm

The Autosampler’s durable electrode holder is able to accommodate three 12 mm electrodes, a temperature sensor, one aspiration tube, five multipurpose tubes, and an overhead stirring assembly, allowing for maximum versatility. The multipurpose spaces can be utilized for a variety of functions including reagent addition or burette dosing.

HI921 Autosampler StatusLights

Autosampler Status Indicator

Highly visible status lights are located on top of the Autosampler. These lights correspond to the status indication on the HI932 titrator display and can clearly be seen from a distance. These indicator lights double as a safety feature and serve to automatically stop the current titration sequence with a simple press.

Carousel Functionality

HI922 carousel

Choice of Sample Trays

The HI922 is able to automate samples using a 16 or 18 sample tray. The 16 sample tray accommodates 150 mL beakers while the 18 sample tray holds 100 mL beakers. The trays are composed of chemically resistant material and are easily removable. Each tray is dishwasher safe, providing a quick and simple way for users to clean regularly.

Automatic Tray Recognition

The HI921 sample trays feature a built-in RFID reader that’s able to detect and communicate the size and serial number of any tray on the carousel. Users can set up multiple trays designated to differing sample sets without confusion. The RFID reader will ensure that the appropriate tray is used each time.

Optical IR Beaker Detection

An optical IR beam is able to detect the presence or absence of each beaker within the sample tray. A user can select which action the HI922 should take if a beaker is missing during a titration sequence. The Autosampler may be programmed to skip the missing beaker, pause, or stop the titration sequence.

Smart Positioning

The HI922 contains an absolute encoder that can track the tray position without needing to return ā€œhomeā€ or calibrate. The encoder retains the position information when powered off and is readily available when powered back on.

Integrated Magnetic Stirrer

A magnetic stirrer comes built into each carousel assembly. Users simply have to add a small magnetic stir bar to each sample beaker to ensure samples are well-mixed during titrations. An optional overhead propeller stirrer may also be installed as an alternative. The HI921 allows you to easily adjust the stirring speed of both the built-in and overhead stirrers for optimal mixing.

Sample Handling & Recording

screenshots 921 2

Expedited Sample Entry

Sample names can be auto-incremented for speedy and convenient sample sample entry.

Configurable Balance Interface

Sample sizes may be automatically communicated from any laboratory analytical balance with a RS232 serial output, saving time and labor.

Flexible Sample Assignment

Up to 18 samples may be run consecutively with the options to accommodate up to 3 rinse beakers and 1 storage beaker.

Organized Sample Table

A USB-compatible barcode reader may be connected to the Autosampler, associating names with samples for improved recordkeeping.

Titration Data & Reporting

HI932 with HI922 autosampler

Customizable Autosampler Sequences

The HI932 can store up to 100 user-defined or standard titration methods that can be accessed by the Autosampler. Each method may be customized and optimized for sequence performance based on application and user requirements.

Detailed Sequence Reports

Autosampler sequence reports detail sample names, beaker positions, sample sizes, and results for the sample tray in addition to detailed titration reports for individual samples.

Customizable Titration Reports

Each titration report is fully customizable so users can be confident they are storing and filing the appropriate data required for their application and procedures.

Specifications

SKU HI922-web
Name Autosampler for Potentiometric Titrator – HI922
Weight 20 lbs

Manuals

Autosampler for Potentiometric Titrator – HI922

Bestsellers

Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

306.00 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafeā„¢ mechanism Adjustable speed control
Inquire Now

NaCl Calibration Salt for Relative Humidity - HI7121/P

553.00 AED
HI7121/P are spare NaCl saturation salts for use with the HI7102 high range humidity calibration (75.4%).
Inquire Now

Calibration Check Key at 32°F (HI765 Probes) - HI765032F

97.00 AED
The HI765032F is a calibration check key for thermistor thermometers that use the HI765 series of probes. Designed to simulate 32℉ (±0.8℉), this key offers a fast and simple way of checking the accuracy of your instrument.
  • 32℉ Key Rated Value
  • Simple, Quick Verification
  • For Thermistors with HI765 Probes
Inquire Now

Compact Magnetic Mini-Stirrer (Blue) - HI180F-1

306.00 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafeā„¢ mechanism Adjustable speed control
Inquire Now

Overhead Stirrer Assembly for Titrator - HI900301

2,855.00 AED
The HI900301 is a replacement overhead stirrer assembly for Hanna’s HI901 and HI902C Automatic Titration Systems. HI900301 includes the overhead stirrer and three chemically resistant propellers.
  • Easy-to-adjust positioning collar
  • Replaceable propellers
  • Dedicated openings for probes and dispensing tube

Maintenance Kit for Turbidity Meter - HI731313

572.00 AED
The HI731313 is a maintenance kit for wiht the HI93703 portable turbidty meters. The maintenance kit includes HI93703-0 (0 FTU), HI93703-05 (500 FTU) and HI93703-10 (10 FTU) calibration solutions along with two spare cuvettes, cuvette cleaning cloth and rugged carrying case that holds the accessories aloing with the ortable turbidity meter.
  • Maintenance kit for HI93703 Portable Turbidity Portable Meter
  • Includes cuvette cleaning accessories, spare cuvettes, and calibration standards
  • Great for environmental, field, and laboratory testing
Inquire Now

Calibration Check Key at 70°C (HI765 Probes) - HI765070C

97.00 AED
The HI765070C is a calibration check key for thermistor thermometers that use the HI765 series of probes. Designed to simulate 70ā„ƒ (±0.4ā„ƒ), this key offers a fast and simple way of checking the accuracy of your instrument.
  • 70ā„ƒ Key Rated Value
  • Simple, Quick Verification
  • For Thermistors with HI765 Probes