Out of stock

Acid Hydrolyzable Phosphorus Reagents with Barcode Recognition – HI94758B-50

The HI94758B-50 are reagents that follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method for the determination of acid hydrolyzable phosphorus using the compatible HI83224 benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.

  • Pre-dosed reagents for ease of use
  • Barcoded vials
  • Marked with expiration date and lot number for traceability

424.00 AED

Inquire Now
SKU:HI94758B-50

The HI94758B-50 reagent kit contains 50 ready-to-use vials of HI94758V-0AH, 1 bottle of HI93758B-0 solution, and 50 packets of HI93758-0 phosphorus reagent. These high quality reagents follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. In this method, the reaction between orthophosphate and the reagent causes a blue tint in the sample. The amount of phosphorus is then measured colorimetrically. The intensity of color is determined by a compatible photometer and the concentration is displayed in mg/L (ppm) of phosphorus. These reagents are designed to be used with samples that have an expected range of 0.00 to 1.60 mg/L (ppm) phosphorus.

Hanna vials contain pre-dosed reagent so the user simply needs to add a small quantity of the sample to the vial followed by heating 30 minutes at 150ā„ƒ and cooling, then the addition of the NaOH solution to use as the blank, followed by the addition of the phosphorus powder reagent to measure the concentration. With pre-dosed vials, test preparation time is dramatically reduced and there is no time-consuming reagent preparation procedure or glassware cleaning. The vials and caps of the reagents have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is also minimized. These vials feature Hanna’s barcode recognition system exclusive to the HI83224 Wastewater Treatment benchtop photometer. The meter scans each vial to automatically identify sample method and range. The barcode has four digits: the first two digits are for parameter identification and the second two digits are for reagent lot ID. Vials for different methods can be distinguished by a barcode printed on the vial and the cap color.

Specifications

SKU HI94758B-50
Name Acid Hydrolyzable Phosphorus Reagents with Barcode Recognition – HI94758B-50
Package Vials, bottle, and packets
Quantity 50 tests
Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method

Manuals

Acid Hydrolyzable Phosphorus Reagents with Barcode Recognition – HI94758B-50

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)

59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

Marine Alkalinity CheckerĀ® HC Reagents (25 Tests) - HI755-26

31.00 AED
The HI755-26 are the replacement reagents for the Marine Alkalinity CheckerĀ® HC - HI755 and Marine Alkalinity (dKH) CheckerĀ® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.

Chromium VI High Range Reagents (100 tests) - HI93723-01

130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
Inquire Now

HI5124 pH 12.45 Technical Calibration Buffer (500 mL)

123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25ā„ƒ
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI70300L Electrode Storage Solution (500 mL)

59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
  • Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
  • Manufactured specifically for pH and ORP electrodes
  • Clearly marked expiration date and lot number