Bestsellers in Products
HI7061L General Purpose Cleaning Solution (500 mL)
61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
- Specially formulated for cleaning electrodes
- Air tight seal to ensure quality
- Expiration date and lot number
HI7034L 80000 µS/cm Conductivity Standard (500mL Bottle)
59.00 AED
HI7034L is a premium quality 80, 000 µS/cm conductivity standard that is prepared against a NIST traceable potassium chloride solution. Hanna conductivity solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of conductivity standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
- Air tight bottle with tamper-proof seal to ensure quality
Marine Alkalinity Checker® HC Reagents (25 Tests) - HI755-26
The HI755-26 are the replacement reagents for the Marine Alkalinity Checker® HC - HI755 and Marine Alkalinity (dKH) Checker® HC - HI772. These high-quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
- Pre-made reagents for ease of use
- Prepared with high purity chemicals
- Marked with expiration date and lot number for traceability
Inquire Now
GroLine pH/EC/TDS Multiparameter Probe (Inline)
989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
- In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
- Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
- Specialized for hydroponics with a renewable junction for extended life.
Chromium VI High Range Reagents (100 tests) - HI93723-01
130.00 AED
The HI93723-01 are reagents for the colorimetric determination of hexavalent chromium (Cr+6) using a compatible benchtop or portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
- Pre-dosed reagents for ease of use
- Supplied with certificate of quality
- Marked with expiration date and lot number for traceability
Inquire Now
HI5124 pH 12.45 Technical Calibration Buffer (500 mL)
123.00 AED
HI5124 is a premium quality pH 12.45 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Supplied with Certificate of Analysis
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
HI70300L Electrode Storage Solution (500 mL)
59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
- Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
- Manufactured specifically for pH and ORP electrodes
- Clearly marked expiration date and lot number
Active filters:
Showing 1–12 of 20 results
HI7061L General Purpose Cleaning Solution (500 mL)
61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
- Specially formulated for cleaning electrodes
- Air tight seal to ensure quality
- Expiration date and lot number
HI70300L Electrode Storage Solution (500 mL)
59.00 AED
HI70300L is a storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any effects of diffusion/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.
- Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte
- Manufactured specifically for pH and ORP electrodes
- Clearly marked expiration date and lot number
HI7007M pH 7.01 Calibration Solution (230 mL)
54.00 AED
HI7007M is a premium quality pH 7.01 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Color coded label for easy pH buffer value identification
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
pHep®4 pH/Temperature Tester - HI98127
391.00 AED
Hanna's pHep®4 waterproof tester is an advanced meter has many features that can be found in portable and benchtop meters. This ergonomic meter measures from -2.0 to 16.0 pH with an accuracy of ±0.1 pH. pHep®4 features automatic one or two-point calibration and automatic temperature compensation. The large multi level LCD display shows both pH and temperature readings simultaneously, while a stability indicator is displayed to alert the user when a stable reading has been obtained. The pHep®4 tester also features a replaceable pH probe that has a unique extendable cloth junction to clear any clogging that occurs.
- Waterproof
- Replaceable pH Electrode
- Automatic Two-Point pH Calibration
GroLine Hydroponics Waterproof pH/EC/TDS/Temperature Portable Meter - HI9814
869.00 AED
The HI9814 is a slim, lightweight, waterproof, portable meter that measures the pH, conductivity (EC), total dissolved solids (TDS), and temperature of nutrient solutions used in hydroponics, aquaponics and greenhouse growing. The meter has two-button operation, one for turning the meter on/off and calibration while the other switches between the measurement modes. The HI9814 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
- 3 in 1 amplified probe with pH, EC/TDS and temperature sensors
- Quick Cal Mode to calibrate pH and EC/TDS with one solution
- EC to TDS Conversion factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)
HI7074L Electrode Cleaning Solution for Inorganic Substances (500 mL)
119.00 AED
The HI7074L is a highly effective cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with inorganic substances. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
- Specially formulated cleaning solution to remove proteins from a pH electrode
- Air tight seal to ensure quality and efficiency of cleaning solution
- Expiration date and lot number clearly marked on the bottle
HI7010/1G pH 10.01 Calibration Solution (1 G ( 3.78 L) )
200.00 AED
HI7010/1G is a premium quality pH 10.01 calibration solution that has been dyed violet for easy buffer identification. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.
- Color coded label for easy pH buffer value identification
- Accuracy of ±0.01 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each bottle
Titanium Body pH Electrode for Boilers and Cooling Towers with BNC + Phono Connector - HI72911B
723.00 AED
The HI72911B is a titanium body, polymer filled, double reference junction pH electrode with a BNC + phono connector. This flat tip sensing portion of this electrode is made with general purpose glass.The HI72911B has a PTFE type junction along with a built-in temperature sensor. This design consideration is ideal for measuring the pH in boilers and cooling towers. The HI72911B is designed for use with Hanna’s HI98191 pH meter.
- Unbreakable Titanium Body
- Built-In Temperature Sensor for Automatic Temperature Compensation
- Large Annular PTFE Junction with Increased Surface Area for the Reference Cell
HI6016 pH 1.679 Millesimal Calibration Buffer (500 mL)
139.00 AED
HI6016 is a premium quality pH 1.679 millesimal calibration buffer with a high accuracy of ±0.002 pH. Millesimal buffer solutions are designed for customers who require a resolution of 0.001 for their pH measurements. The HI6016 is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of millesimal calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
- Supplied with Certificate of Analysis
- Accuracy of ±0.002 pH @ 25℃
- Temperature chart of the actual pH value at various temperatures printed on each sachet
Foodcare pH Electrode for Meat and Semi-Frozen Products with BNC Connector - FC230B
935.00 AED
=The FC230B is a PVDF body, single junction pH electrode that has a BNC connector. The FC230B electrode features an open junction design with viscolene gel electrolyte, a sensing bulb made of low temperature glass, and a conical tip shape.
This design consideration, along with the optional stainless steel blades, is ideal for pH measurements in products such as meats and semi-frozen food products. The recommended operating temperature range is from 0 to 50℃.
Low Temperature Glass
Stainless Steel Piercing Blade (optional)
Open Junction
Waterproof pHep®5 pH/Temperature Tester - HI98128
433.00 AED
Hanna's pHep®5 is an advanced, ergonomic, waterproof pH and temperature tester, with 0.01 resolution, that measures from -2.0 to 16.0 pH pH and accuracy of ±0.05 pH. pHep5 features automatic one or two-point calibration to known buffer and automatic temperature compensation.
- Waterproof
- Replaceable pH Electrode
- Automatic up to Three-Point pH Calibration
Checker® pH Tester with 0.1 pH Resolution - HI98103
132.00 AED
The HI98103 Checker is the next generation of the original Hanna Checker pH tester. The Checker is the most popular pH meter in the world with over 1 million meters used since its introduction in 1991. From students to researchers, the Checker has been helping people with their pH measurement as a meter that is simple to use and operate.
- One-button operation
- Replaceable pH electrode
- ±0.2 pH accuracy