Turbidimeter


Turbidity (EPA) and Chlorine Portable Meter
Model No : HI93414

Pool Line ISO Portable Turbidity Meter
Model No : HI987134-01
Turbidity (EPA) and Chlorine Portable Meter
Specifications
×
| SKU | HI93414-02 |
|---|---|
| Product Name | Turbidity (EPA) and Chlorine Portable Meter - HI93414 |
| Quote Required | Yes |
| Turbidity Range | 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU |
| Turbidity Resolution | 0.01; 0.1; 1 NTU |
| Turbidity Accuracy | ±2% of reading plus 0.02 NTU |
| Turbidity Repeatability | ±1% of reading or 0.02 NTU, whichever is greater |
| Turbidity Stray Light | < 0.02 NTU |
| Turbidity Calibration | two, three, or four-point calibration |
| Turbidity Measuring Method | ratio nephelometric method (90° & 180°) |
| Turbidity Measuring Modes | normal, average, continuous |
| Turbidity Light Source | tungsten filament lamp |
| Turbidity Light Detector | silicon photocell |
| Logging Memory | 200 records |
| Connectivity | USB or RS232 |
| Automatic Shut-Off | auto-off after 15 minutes of non-use |
| Display | 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight |
| Battery Type/Life | 4 (1.5V) AA alkaline batteries |
| Power Supply | 4 (1.5V) AA alkaline batteries or AC adapter |
| Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
| Dimensions | 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) |
| Weight | 512 g (18 oz.) |
| Photometer/Colorimeter Light Source | Tungsten filament lamp |
| Photometer/Colorimeter Light Detector | Silicon photocell with 525 nm narrow band interference filters |
| Ordering Information | HI93414 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity and chlorine, silicone oil, cuvette wiping cloth, scissors, batteries, AC adapter, instruction manual, and rugged carrying case. |
| Free Chlorine Range | 0.00 to 5.00 mg/L |
| Free Chlorine Resolution | 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L |
| Free Chlorine Accuracy | ±0.02 mg/L @ 1.00 mg/L |
| Total Chlorine Range | 0.00 to 5.00 mg/L |
| Total Chlorine Resolution | 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L |
| Total Chlorine Accuracy | ±0.02 mg/L @ 1.00 mg/L |
| Chlorine Method | Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample. |
Pool Line ISO Portable Turbidity Meter
Specifications
×
| SKU | HI987134-01 |
|---|---|
| Product Name | Pool Line ISO Portable Turbidity Meter – HI987134 |
| Quote Required | Yes |
| GPS | Yes |
| Turbidity Range | 1.0 to 9.99; 10.0 to 99.9; 100 to 1000 NTU |
| Turbidity Resolution | 0.1; 0.1; 1 FNU |
| Turbidity Accuracy | ±2% of reading plus 0.1 FNU |
| Turbidity Repeatability | ±1% of reading or 0.01 FNU, whichever is greater |
| Turbidity Stray Light | < 0.1 FNU |
| Turbidity Calibration | Two, three, or four-point calibration |
| Turbidity Measuring Method | Ratio nephelometric method (90° & 180°). Adaptation of ISO 7027 |
| Turbidity Measuring Modes | Normal, average, continuous |
| Turbidity Light Source | 860 nm infrared LED |
| Turbidity Light Detector | Silicon Photocell |
| Connectivity | USB or RS232 |
| Automatic Shut-Off | Auto-off after 15 minutes of non-use |
| Display | 60 x 90 mm LCD with backlight |
| Battery Type/Life | (4) 1.5V AA batteries / AC adapter |
| Environment | 0 to 50°C (32 to 122 °F); RH max 95% non-condensing |
| Dimensions | 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) |
| Weight | 512 g (18 oz.) |
| Ordering Information | HI987134 is supplied with sample cuvettes and caps (5), HI98713-11 calibration cuvettes, silicone oil, cuvette wiping cloth, batteries, AC adapter, instructions, and rugged carrying case. |