Titrators and Mini Titrators – Precision Titration Solutions in UAE & Oman
At Chemstock, we offer a comprehensive selection of titrators and mini titrators designed to deliver accurate and reliable results for various applications. As the exclusive supplier of Hanna Instruments in the UAE and Oman, we provide the latest in titration technology, including Karl Fischer, potentiometric, and automated titrators to meet the needs of laboratories, industrial settings, and educational institutions.
Wide Range of Titrators to Suit Your Needs
Karl Fischer Titration for Moisture Analysis
Our Karl Fischer titrators are ideal for moisture determination in various samples. Whether you need volumetric Karl Fischer titration for high water content or coulometric Karl Fischer titration for trace amounts, our titrators provide fast and precise results.
Potentiometric Titration for Versatile Applications
Potentiometric titration is essential for accurate pH determination, acidity, and other chemical properties. Our digital and automatic potentiometric titrators offer user-friendly interfaces and programmable methods to streamline titration processes.
Automatic and Mini Titrators for Effortless Operation
For laboratories requiring automation, our automatic titrators ensure consistency and efficiency. Our mini titrators are perfect for fieldwork and educational settings where space and budget are limited.

Automatic Potentiometric Titrator
Model No : HI931-02

Automatic Potentiometric Titrator
Model No : HI932-02

Volumetric Karl Fischer Titrator
Model No : HI933-02

Coulometric Karl Fischer Titrator
Model No : HI934-02
Automatic Potentiometric Titrator
Specifications
| SKU | HI931-02 |
|---|---|
| Product Name | Automatic Potentiometric Titrator - HI931 |
| Quote Required | Yes |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| mV Calibration | single point offset |
| pH Range | -2.000 to 20.000 pH; -2.00 to 20.00 pH; -2.0 to 20.0 pH |
| pH Resolution | 0.001 pH; 0.01 pH; 0.1 pH |
| pH Accuracy | ±0.001 pH |
| pH Calibration | up to five-point calibration, eight standard buffers and five custom buffers |
| pH Temperature Compensation | automatic from -5.0 to 105.0°C; 23.0 to 221.0°F |
| ISE Range | 1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration |
| ISE Resolution | 1; 0.1; 0.01 concentration |
| ISE Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) |
| ISE Calibration | automatic, up to five point calibration, seven fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 choice of concentration) and five custom solutions |
| Temperature Range | -5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K |
| Temperature Resolution | 0.1°C; 0.1°F; 0.1K |
| Temperature Accuracy | ±0.1°C; ±0.2°F; ±0.1K, excluding probe error |
| Potentiometric Titrations | acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric |
| Analog Boards Capability | one analog board for pH/ORP/ISE; not upgradeable |
| Measurement Units | user-specified expression of concentration units to suit specific calculation requirements |
| Endpoint Criteria | single equivalence point (1st or 2nd derivative) or fixed pH/mV value |
| Dosing Pump Capability | one included can be upgraded for two |
| Flow Rate | user-selectable from 0.1 mL/min to 2 x burette volume/min |
| Dosing Accuracy | ±0.1% of full burette volume |
| Burette | one 25 mL burette included |
| Burette Size Capability | 5, 10, 25, and 50 mL (auto-detection) |
| Dosing Pump Resolution | 1/40000 |
| Stirrer Type | overhead propeller type, 200 to 2500 rpm, resolution 100 rpm |
| Titrator Methods | up to 100 methods (standard and user-defined) |
| Linked Methods | not available |
| Back Titrations | not available |
| Real Time & Stored Graphs | mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode |
| GLP Conformity | instrumentation data storage and printing capabilities |
| Autosampler Compatible | not available |
| Logging Memory | up to 100 titration and pH/mV/ISE reports |
| Connectivity | USB |
| Display | 5.7” (320 x 240 pixel) backlit color LCD |
| Power Supply | 100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C) |
| Environment | Operating |
| Dimensions | 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 ") |
| Weight | approx. 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors |
| Ordering Information | Each HI931 potentiometric titrator is supplied with titrator, pump assembly, burette assembly, electrodes holder and stirrer, burette blank support, pump and burette locking screws with plastic head, temperature probe, shorting cap, power adapter, USB cable, instruction manual, USB Memory Stick, HI900 PC application (installation kit on USB stick), and quality certificate. |
Automatic Potentiometric Titrator
Specifications
| SKU | HI932C-02-web |
|---|---|
| Product Name | Automatic Potentiometric Titrator - HI932 |
| Quote Required | Yes |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| mV Calibration | single point offset |
| pH Range | -2.000 to 20.000 pH; -2.00 to 20.00 pH; -2.0 to 20.0 pH |
| pH Resolution | 0.001 pH; 0.01 pH; 0.1 pH |
| pH Accuracy | ±0.001 pH |
| pH Calibration | up to five-point calibration, eight standard buffers and five custom buffers |
| pH Temperature Compensation | automatic from -5.0 to 105.0°C; 23.0 to 221.0°F |
| ISE Range | 1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration |
| ISE Resolution | 1; 0.1; 0.01 concentration |
| ISE Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) |
| ISE Calibration | automatic, up to five point calibration, seven fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 choice of concentration) and five custom solutions |
| Temperature Range | -5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K |
| Temperature Resolution | 0.1°C; 0.1°F; 0.1K |
| Temperature Accuracy | ±0.1°C; ±0.2°F; ±0.1K, excluding probe error |
| Potentiometric Titrations | acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric |
| Analog Boards Capability | can be ordered with one or two analog boards for pH/ORP/ISE HI932C1 supplied with one analog board can be upgraded to have two |
| Measurement Units | user-specified expression of concentration units to suit specific calculation requirements |
| Endpoint Criteria | single equivalence point (1st or 2nd derivative) or fixed pH/mV value |
| Dosing Pump Capability | one included can be upgraded for two |
| Flow Rate | user-selectable from 0.1 mL/min to 2 x burette volume/min |
| Dosing Accuracy | ±0.1% of full burette volume |
| Burette | one 25 mL burette included |
| Burette Size Capability | 5, 10, 25, and 50 mL (auto-detection) |
| Dosing Pump Resolution | 1/40000 |
| Stirrer Type | overhead propeller type, 200 to 2500 rpm, resolution 100 rpm |
| Titrator Methods | up to 100 methods (standard and user-defined) |
| Linked Methods | yes |
| Back Titrations | yes |
| Real Time & Stored Graphs | mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode |
| GLP Conformity | instrumentation data storage and printing capabilities |
| Autosampler Compatible | yes |
| Logging Memory | up to 100 titration and pH/mV/ISE reports |
| Connectivity | USB |
| Display | 5.7” (320 x 240 pixel) backlit color LCD |
| Power Supply | 100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C) |
| Environment | Operating |
| Dimensions | 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 ") |
| Weight | approx. 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors |
| Ordering Information | HI932C1 (1 analog board for potentiometric probe) and HI932C2 (2 analog board for potentiometric probe) titrators are supplied with titrator, pump assembly, burette assembly, electrodes holder and stirrer, burette blank support, pump and burette locking screws with plastic head, temperature probe, shorting cap, power adapter, USB cable, instruction manual, USB Memory Stick, HI900 PC application (installation kit on USB stick), and quality certificate. |
Volumetric Karl Fischer Titrator
Specifications
| SKU | HI933-02 |
|---|---|
| Product Name | Volumetric Karl Fischer Titrator - HI933 |
| Quote Required | Yes |
| Titration Range | 100 ppm to 100% |
| Titration Resolution | 1 ppm to 0.0001% |
| Measurement Units | %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc |
| Sample Type | liquid or solid |
| Pre-Titration Conditioning | automatic |
| Background Drift Correction | automatic or user-selectable value |
| Endpoint Criteria | fixed mV persistence, relative drift stop or absolute drift stop |
| Dosing Type | dynamic with optional pre-dispensing |
| Result Statistics | mean, standard deviation |
| Dosing Accuracy | ±0.1% of full burette volume |
| Syringe | 5 mL precision ground glass with PTFE plunger |
| Valve | motor-driven 3-way, PTFE liquid contact material |
| Tubing | PTFE with light block and thermal jacketing |
| Dispensing Tip | glass, fixed position, anti-diffusing |
| Titration Vessel | conical with operation volume between 50 and 150 mL |
| Solvent Handling System | sealed system, integrated diaphragm air pump |
| Connection Type | BNC |
| Polarization Current | 1, 2, 5, 10, 15, 20, 30 or 40 uA |
| mV Range | 2 mV to 1000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% |
| Burette | 5 mL burette |
| Dosing Pump Resolution | 1/40000 of the burette volume (0.125 μL per dose) with 5 mL burette |
| Stirrer Type | magnetic, optically regulated, digital stirre |
| Stirrer Speed | 200 - 2000 RPM |
| Stirrer Resolution | 100 RPM |
| Titrator Methods | up to 100 standard and user defined |
| Reports | up to 100 complete titration reports and drift rate reports |
| Connectivity | USB |
| Built-in Magentic Stirrer | magnetic, optically regulated, digital stirrer; 200 to 2000 rpm; resolution 100 rpm |
| Display | 5.7” graphical color display with backlight |
| Keypad | polyester |
| Languages | English, Portuguese, Spanish, and French |
| Power Supply | 100-240 Vac, 50/60 Hz / 0.5 Amps |
| Environment | Operating |
| Dimensions | 315 x 205 x 375 mm (12.4 x 8.1 x 14.8") |
| Weight | Approximate 4.3 kg (9.5 lbs) with 1 pump, stirrer and sensors |
| Ordering Information | HI933 is supplied with HI76320 dual platinum pin electrode, dosing pump, 5 mL burette assembly with tubing, air pump/stirrer assembly with tubing, beaker and bottle top assemblies and all fittings, desiccant cartridges (4) with indicator desiccant, stir bar, waste bottle, calibration key, USB cable, power cable, USB flash drive, quality certificate, ISO 8655 burette compliance report, and instruction manual binder |
Coulometric Karl Fischer Titrator
Specifications
| SKU | HI934-02-web |
|---|---|
| Product Name | Coulometric Karl Fischer Titrator - HI934 |
| Quote Required | Yes |
| Titration Principle | coulometric Karl Fischer |
| Titration Range | 1 ppm to 5% |
| Titration Resolution | 0.1ppm to 0.0001% |
| Measurement Units | %, ppm, ppt, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg Br/100g, g Br/100g, mg Br, g Br |
| Sample Type | liquid or solid with external dissolution / extraction |
| Pre-Titration Conditioning | automatic |
| Background Drift Correction | automatic or user-selectable value |
| Endpoint Criteria | fixed mV persistence, relative drift stop or absolute drift stop |
| Dosing Type | dynamic with optional pre-dispensing rate |
| Result Statistics | mean, standard deviation |
| Titration Vessel | operating volume between 100 – 200 mL |
| Solvent Handling System | sealed system, integrated diaphragm air pump |
| Connection Type | BNC |
| Polarization Current | 1, 2, 5, or 10 μA |
| mV Range | 2 mV to 1100 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% |
| Stirrer Type | magnetic, optically regulated, digital stirrer |
| Stirrer Speed | 200 to 2000 rpm |
| Stirrer Resolution | 100 rpm |
| Titrator Methods | up to 100 methods (standard and user-defined) |
| Reports | up to 100 complete titration reports and drift rate reports can be stored |
| GLP Conformity | Good Laboratory Practice and instrument data storage and printing |
| Peripheral Devices | connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232 |
| Display | 5.7” (320 x 240 pixel) color LCD |
| Keypad | polycarbonate |
| Languages | English, Portuguese. Spanish, and French |
| Power Supply | 100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C) |
| Environment | operating |
| Dimensions | 315 x 205 x 375 mm (12.4 x 8.1 x 14.8 ") |
| Weight | approximate 4.3 kg (9.5 lbs.) |

Sulfur Dioxide Mini Titrator for Wine Analysis, 230V
Model No : HI84500-02

Titratable Acidity Mini Titrator for Dairy Analysis
Model No : HI84529-02

Titratable Alkalinity Mini Titrator for Water
Model No : HI845231-02

Titratable Acidity Mini Titrator for Fruit Juice Analysis
Model No : HI84532-02
Sulfur Dioxide Mini Titrator for Wine Analysis, 230V
Specifications
| SKU | HI84500-02 |
|---|---|
| Product Name | Sulfur Dioxide Mini Titrator for Wine Analysis, 230V |
| Stock Status Message | Pre-order, Ships within 7-8 Weeks |
| Quote Required | No |
| pH-mV Range | -2000.0 to 2000.0 mV |
| pH-mV Resolution | 0.1 mV |
| pH-mV Accuracy | ±1.0 mV (@25ºC/77ºF) |
| Titration Method | Ripper method |
| Titration Principle | equivalence point redox titration |
| Titration Range | Low Range |
| Titration Resolution | Low Range |
| Titration Accuracy | Low Range |
| Sample Size | 50 mL |
| Titration Pump Speed | 10 mL/min |
| ORP Electrode | HI3148B glass body ORP electrode with BNC connector and 1 m (3.3’) cable (included) |
| Logging Type | log-on-demand |
| Logging Memory | up to 400 (200 titrations, 200 ORP/mV readings) |
| Built-in Magentic Stirrer | Built-in magnetic stirrer at 700 rpm |
| Power Supply | 12 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Dimensions | 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”) |
| Weight | 1.9 kg (67.0 oz.) |
| Ordering Information | HI84500-01 (115V) is supplied with HI3148B ORP electrode, HI7082 electrode fill solution (30 mL), HI84500-50 low range titrant (230 mL), HI84500-51 high range titrant (230 mL), HI84500-55 calibration standard (120 mL), HI84500-60 acid reagent (230 mL), HI84500-61 alkaline reagent (120 mL), and HI84500-62 stabilizer packets (50 packets), 100 mL beakers (2), 20 mL beakers (2), scissors, dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, cleaning solution sachets for wine deposits (2), cleaning solution sachets for wine stains (2), 12 VDC adapter and instruction manual. |
| Hsn Code | 90275090 |
Titratable Acidity Mini Titrator for Dairy Analysis
Specifications
| SKU | HI84529-02 |
|---|---|
| Product Name | Titratable Acidity Mini Titrator for Dairy Analysis, 230V |
| Stock Status Message | Pre-order, Ships within 7-8 Weeks |
| Quote Required | No |
| pH-mV Range | -2000.0 to 2000.0 mV |
| pH-mV Resolution | 0.1 mV |
| pH-mV Accuracy | ±1.0 mV |
| pH Range | -2.0 to 16.0 pH; -2.00 to 16.00 pH |
| pH Resolution | 0.1 pH / 0.01 pH |
| pH Accuracy | ±0.01 pH (@25ºC/77ºF) |
| pH Calibration | one, two or three-point calibration; four available buffers (4.01, 6.00, 8.30, 10.01) |
| pH Temperature Compensation | manual or automatic |
| Temperature Range | -20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K |
| Temperature Resolution | 0.1°C; 0.1°F; 0.1K |
| Temperature Accuracy | ±0.4°C; ±0.8°F; ±0.4 K (@25ºC/77ºF), without probe error |
| Titration Method | acid base titration |
| Titration Principle | endpoint titration, adjustable (pH 8.0 - 8.7 in 0.1 increments) |
| Titration Range | Low Range |
| Titration Resolution | Low Range |
| Titration Accuracy | Low Range |
| Sample Size | LR 20 |
| Titration Pump Speed | 10 mL/min |
| pH Electrode | FC260B pH electrode with 1 m (3.3’) cable (included), HI5315 reference electrode with 1 m (3.3’) cable (included) |
| Temperature Probe | HI7662-M temperature probe with 1 m (3.3’) cable (included) |
| Logging Type | Log-on-demand |
| Logging Memory | up to 400 ( 200 titrations, 200 pH/mV readings) |
| Connectivity | 1 USB port for data storage and export to a PC |
| Built-in Magentic Stirrer | Built-in magnetic stirrer at 800 rpm (Low Range) / 1000 rpm (High Range) |
| Power Supply | 12 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Dimensions | 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”) |
| Weight | 1.9 kg (67.0 oz.) |
| Ordering Information | HI84529-01 is supplied with FC260B pH electrode, HI5315 reference electrode, HI7662-M temperature probe, HI84529-50 low range 20 titrant (120 mL), HI84529-52 low range 50 titrant (120 mL), HI84529-51 high range 20 titrant (120 mL), HI84529-55 calibration standard (230 mL), HI7072 fill solution (30 mL), HI700640 cleaning solution for milk deposits (2 x 20 mL), capillary dropper pipette, 100 mL beakers (2), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, 12VDC power adapter, instruction manual and quality certificate. |
| Hsn Code | 90275090 |
Titratable Alkalinity Mini Titrator for Water
Specifications
| SKU | HI84531-02 |
|---|---|
| Product Name | Titratable Alkalinity Mini Titrator for Water Analysis, 230V |
| Stock Status Message | Pre-order, Ships within 7-8 Weeks |
| Quote Required | No |
| pH-mV Range | -2000.0 to 2000.0 mV |
| pH-mV Resolution | 0.1 mV |
| pH-mV Accuracy | ±1.0 mV (@25ºC/77ºF) |
| pH Range | -2.0 to 16.0 pH; -2.00 to 16.00 pH |
| pH Resolution | 0.1 pH / 0.01 pH |
| pH Accuracy | ±0.01 pH (@25ºC/77ºF) |
| pH Calibration | one, two or three-point calibration; four available buffers (4.01, 7.01, 8.30, 10.01) |
| pH Temperature Compensation | manual or automatic |
| Temperature Range | -20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K |
| Temperature Resolution | 0.1°C; 0.1°F; 0.1K |
| Temperature Accuracy | ±0.4°C; ±0.8°F; ±0.4 K (@25ºC/77ºF), without probe error |
| Titration Method | acid-base titration (strong alkalinity/total alkalinity) |
| Titration Principle | endpoint titration |
| Titration Range | Low Range |
| Titration Resolution | Low Range |
| Titration Accuracy | Low Range |
| Sample Size | Low Range |
| Titration Pump Speed | 10 mL/min |
| pH Electrode | HI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included) |
| Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) |
| Logging Type | Log-on-demand |
| Logging Memory | up to 400 ( 200 titrations, 200 pH/mV readings) |
| Connectivity | 1 USB port for data storage and export to a PC |
| Built-in Magentic Stirrer | Built-in magnetic stirrer at 600 rpm |
| Power Supply | 12 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Dimensions | 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”) |
| Weight | 1.9 kg (67.0 oz.) |
| Ordering Information | HI84531 is supplied with HI1131B pH electrode, HI7662-M temperature probe, HI84531-50 low range titrant (120 mL), HI84531-51 high range titrant (120 mL), HI84531-55 calibration standard (230 mL), 100 mL beakers (2), dosing pump valve, 5 mL syringe, 2000 µL automatic pipette with two plastic tips, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate. |
| Hsn Code | 90275090 |
Titratable Acidity Mini Titrator for Fruit Juice Analysis
Specifications
| SKU | HI84532-02 |
|---|---|
| Product Name | Titratable Acidity Mini Titrator for Fruit Juice Analysis, 230V |
| Stock Status Message | Pre-order, Ships within 7-8 Weeks |
| Quote Required | No |
| pH-mV Range | -2000.0 to 2000.0 mV |
| pH-mV Resolution | 0.1 mV |
| pH-mV Accuracy | ±1.0 mV (@25ºC/77ºF) |
| pH Range | -2.0 to 16.0 pH; -2.00 to 16.00 pH |
| pH Resolution | 0.1 pH / 0.01 pH |
| pH Accuracy | ±0.01 pH (@25ºC/77ºF) |
| pH Calibration | one, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01) |
| pH Temperature Compensation | manual or automatic |
| Temperature Range | -20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K |
| Temperature Resolution | 0.1°C; 0.1°F; 0.1K |
| Temperature Accuracy | ±0.4°C; ±0.8°F; ±0.4 K (@25ºC/77ºF), without probe error |
| Titration Method | acid base titration |
| Titration Principle | endpoint titration |
| Titration Range | Low Range (g/100 mL) |
| Titration Resolution | 0.01% |
| Titration Accuracy | ±0.02% or 3% of reading CA whichever is greater (@25ºC/77ºF) |
| Sample Size | Low Range |
| Titration Pump Speed | 10 mL/min |
| pH Electrode | HI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included) |
| Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) |
| Logging Type | Log-on-demand |
| Logging Memory | up to 400 ( 200 titrations, 200 pH/mV readings) |
| Connectivity | 1 USB port for data storage and export to a PC |
| Built-in Magentic Stirrer | Built-in magnetic stirrer at 600 rpm |
| Power Supply | 12 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Dimensions | 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”) |
| Weight | 1.9 kg (67.0 oz.) |
| Ordering Information | HI84532 is supplied with HI1131B pH electrode, HI84532-50 low range titrant (100 mL), HI84532-51 high range titrant (100 mL), HI84532-55 calibration standard (100 mL), HI7662-T temperature probe, HI7082 electrode fill solution (30 mL), 100 mL beakers (2), 20 mL beaker, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, stir bar, power adapter, instruction manual and quality certificate. |
| Hsn Code | 90275090 |