pHep®4 pH/Temperature Tester
Model No : HI98127

GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester
Model No : HI98131
pHep®4 pH/Temperature Tester
Specifications
×
SKU | HI98127 |
---|---|
Product Name | pHep®4 pH/Temperature Tester - HI98127 |
Quote Required | Yes |
pH Range | -2.0 to 16.0 pH |
pH Resolution | 0.1 pH |
pH Accuracy | ±0.1 pH |
pH Calibration | automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) |
pH Temperature Compensation | automatic |
Temperature Range | -5.0 to 60.0°C / 23.0 to 140.0°F |
Temperature Resolution | 0.1°C / 0.1°F |
Temperature Accuracy | ±0.5°C /±1°F |
pH Electrode | HI73127 replaceable pH electrode (included) |
Temperature Probe | integrated thermistor |
Automatic Shut-Off | after 8 minutes of non-use |
Battery Type/Life | 1.5V (4) / approx. 300 hours of continuous use |
Environment | -5 to 50°C (23 to 122°F); RH max 100% |
Dimensions | 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’) |
Weight | 100 g (3.5 oz.) |
Ordering Information | HI98127 (pHep®4) is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries and instructions. |
GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester
Specifications
×
SKU | HI98131 |
---|---|
Product Name | GroLine Hydroponic Waterproof Pocket pH/EC/TDS/Temperature Tester - HI98131 |
Quote Required | Yes |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.1 pH |
pH Calibration | automatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution |
pH Temperature Compensation | automatic |
EC Range | 0.00 to 6.00 mS/cm |
EC Resolution | 0.01 mS/cm |
EC Accuracy | ±2% F.S. |
EC Calibration | automatic, one-point at 1.41 mS/cm or 5.00 mS/cm; one point calibration using quick calibration solution |
TDS Range | 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF) |
TDS Resolution | 10 ppm (mg/L) |
TDS Accuracy | ±2% F.S. |
TDS Calibration | done through conductivity |
EC/TDS Temperature Compensation | EC/TDS |
EC to TDS Conversion Factor | 0.5 (500 ppm) or 0.7 (700 ppm) |
Cell Type | amperometric two pole |
Temperature Range | 0.0 to 60.0°C / 32.0 to 140.0°F |
Temperature Resolution | 0.1°C / 0.1°F |
Temperature Accuracy | ±0.5°C /±1°F |
Automatic Shut-Off | auto-off after 8 minutes of non-use |
Battery Type/Life | 1.5V (4) / approx. 100 hours of continuous use |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions | 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’) |
Weight | 100 g (3.5 oz.) |
Ordering Information | HI98131 is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries (4), instructions and quality certificate. |