Multiparameter
Waterproof Portable Dissolved Oxygen and BOD Meter
Model No : HI98193
Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter
Model No : HI98194
Waterproof Portable Dissolved Oxygen and BOD Meter
Specifications
×
SKU | HI98193-web |
---|---|
Product Name | Waterproof Portable Dissolved Oxygen and BOD Meter - HI98193 |
Stock Status Message | Ships within 24 hours (In Business Days) |
Quote Required | No |
Dissolved Oxygen Measurement Type | polarographic |
Dissolved Oxygen Range | 0.00 to 50.00 ppm (mg/L); 0.0 to 600.0% saturation |
Dissolved Oxygen Resolution | 0.01 ppm (mg/L); 0.1% saturation |
Dissolved Oxygen Accuracy | ±1.5% of reading ±1 digit |
Dissolved Oxygen Calibration | automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L) |
Dissolved Oxygen Temperature Compensation | automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F) |
Barometric Pressure Compensation | automatic from 450 to 850 mmHg |
Salinity Compensation | automatic from 0 to 70 g/L |
Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy | ±0.2°C; ±0.4°F (excluding probe error) |
DO Probe | HI764073 polarographic DO probe with protective sleeve, internal temperature sensor, DIN connector and 4m (13’) cable (included) |
Logging Type | Log-on-demand |
Logging Memory | up to 400 samples |
Connectivity | opto-isolated USB with optional HI 92000 software and micro USB cable |
Automatic Shut-Off | user selectable |
BOD/OUR/SOUR | direct DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate) |
Battery Type/Life | 1.5V AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with backlight) |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98193 is supplied with HI764073 DO probe, preformed PTFE membrane cap (2), HI7041S electrolyte solution (30 mL), HI7040 bicomponent zero oxygen solution, 100 mL plastic beakers (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, instrument quality certificate and HI760193 rugged carrying case. |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15% from calibration point |
Atmospheric Pressure Calibration | automatic at one custom point |
Hsn Code | 90275090 |
Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter
Specifications
×
SKU | HI98194-web |
---|---|
Product Name | Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter - HI98194 |
Quote Required | Yes |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.02 pH |
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
ORP Range | ±2000.0 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±1.0 mV |
ORP Calibration | automatic at one custom point (relative mV) |
mV Range | ±600.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.5 mV |
EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
EC Resolution | auto-ranging |
EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
TDS Resolution | manual |
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
TDS Calibration | based on conductivity or salinity calibration |
Salinity (PSU) Range | 0.00 to 70.00 PSU |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
Salinity (PSU) Calibration | based on conductivity calibration |
Salinity (Seawater Sigma) Range | 0.0 to 50.0 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Resolution | 0.1 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Accuracy | ±1 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Calibration | based on conductivity or salinity calibration |
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resistivity Resolution | dependent on resistivity reading |
Resistivity Calibration | based on conductivity calibration |
Dissolved Oxygen Measurement Type | Polarographic |
Dissolved Oxygen Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
Dissolved Oxygen Resolution | 0.1%; 0.01 ppm (mg/L) |
Dissolved Oxygen Accuracy | 0.0 to 300.0% saturation |
Dissolved Oxygen Calibration | automatic one or two points at 0 and 100% or one custom point |
Dissolved Oxygen Temperature Compensation | automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F) |
Barometric Pressure Compensation | automatic from 450 to 850 mmHg |
Salinity Compensation | automatic from 0 to 70 g/L |
Temperature Range | Temperature Range |
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration | automatic at one custom point |
Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
Logging Memory | 45,000 records (continuous logging or log-on-demand of all parameters) |
Logging Interval | one second to three hours |
Connectivity | USB to PC with HI9298194 Hanna software installed |
Battery Type/Life | 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98194 is supplied with HI7698194 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert. |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15% from calibration point |
Atmospheric Pressure Calibration | automatic at one custom point |