Electrods (pH & ORP)
Refillable Combination ORP Electrode with BNC Connector
Model No : HI3131B
Gel Filled PEI Body ORP Electrode with BNC Connector
Model No : HI3230B
Digital Glass Body pH Electrode for Hydrocarbons and Solvents
Model No : HI10430
Digital Glass Body pH Electrode with Clogging Prevention System
Model No : HI10480
Refillable Combination ORP Electrode with BNC Connector
Specifications
×
SKU | HI3131B |
---|---|
Product Name | Refillable Combination ORP Electrode with BNC Connector - HI3131B |
Quote Required | Yes |
Measurement Range | ORP |
Reference Cell Type | single, Ag/AgCl |
Junction Type/Flow Rate | ceramic, single / 15-20 μL/h |
Refill Electrolyte | 3.5M KCl + AgCl |
Body Material | glass |
Tip / Shape | platinum pin |
Matching Pin | no |
Max. Pressure | 0.1 bar |
Temperature Operating Range | -5 to 70°C (23 to 158°F) |
Body Length/Overall Length | 150 mm / 205.5 mm |
Temperature Sensor | no |
Outer Diameter | 12 mm |
Cable | coaxial; 1 m (3.3’) |
Connector Type | BNC |
Amplifier | no |
Recommended Use | general purpose, laboratory general purpose, ORP titrations |
ORP Sensing Type | Platinum |
Gel Filled PEI Body ORP Electrode with BNC Connector
Specifications
×
SKU | HI3230B |
---|---|
Product Name | Gel Filled PEI Body ORP Electrode with BNC Connector - HI3230B |
Quote Required | Yes |
Measurement Range | ORP |
Reference Cell Type | single, Ag/AgCl |
Junction Type/Flow Rate | ceramic, single |
Type of Electrolyte | gel |
Body Material | PEI |
Tip / Shape | platinum pin |
Matching Pin | no |
Max. Pressure | 2 bar |
Temperature Operating Range | -5 to 70°C (23 to 158°F) |
Body Length/Overall Length | 120 mm / 163.5 mm |
Temperature Sensor | no |
Outer Diameter | 12 mm |
Cable | coaxial; 1 m (3.3’) |
Connector Type | BNC |
Amplifier | no |
Recommended Use | municipal water, quality control |
ORP Sensing Type | Platinum |
Digital Glass Body pH Electrode for Hydrocarbons and Solvents
Specifications
×
SKU | HI10430 |
---|---|
Product Name | Digital Glass Body pH Electrode for Hydrocarbons and Solvents - HI10430 |
Quote Required | Yes |
Measurement Range | pH |
Reference Cell Type | double |
Junction Type/Flow Rate | ceramic, triple / 40-50 μL/h |
Refill Electrolyte | 3.5M KCl |
Body Material | glass |
Tip / Shape | spheric (dia |
Matching Pin | no |
Max. Pressure | 0.1 bar |
Temperature Operating Range | -5 to 100°C (23 to 212°F) |
Body Length/Overall Length | 120 mm / 175.5 mm |
Temperature Sensor | yes |
Outer Diameter | 12 mm |
Cable | coaxial; 1 m (3.3’) |
Connector Type | 3.5 mm connector |
Amplifier | no |
Recommended Use | hydrocarbon, low conductivity solutions, paints, sea water, solvents, strong acid and base, tris buffer |
Digital Glass Body pH Electrode with Clogging Prevention System
Specifications
×
SKU | HI10480 |
---|---|
Product Name | Digital Glass Body pH Electrode with Clogging Prevention System (CPS™) - HI10480 |
Quote Required | Yes |
Measurement Range | pH |
Reference Cell Type | double |
Junction Type/Flow Rate | open, CPS technology |
Refill Electrolyte | 3.5M KCl |
Body Material | glass |
Tip / Shape | spheric |
Matching Pin | no |
Max. Pressure | 0.1 bar |
Temperature Operating Range | 0 to 80°C (32 to 176°F) |
Body Length/Overall Length | 120 mm / 175.5 mm |
Temperature Sensor | yes |
Outer Diameter | 12 mm |
Cable | coaxial; 1 m (3.3’) |
Connector Type | 3.5 mm connector |
Amplifier | no |
Recommended Use | application specific purpose, samples with suspended solids, wine |
Notes | Compatible Meters |