Electrods (pH & ORP)


Refillable Combination ORP Electrode with BNC Connector
Model No : HI3131B

Gel Filled PEI Body ORP Electrode with BNC Connector
Model No : HI3230B

Digital Glass Body pH Electrode for Hydrocarbons and Solvents
Model No : HI10430

Digital Glass Body pH Electrode with Clogging Prevention System
Model No : HI10480
Refillable Combination ORP Electrode with BNC Connector
Specifications
×
| SKU | HI3131B |
|---|---|
| Product Name | Refillable Combination ORP Electrode with BNC Connector - HI3131B |
| Quote Required | Yes |
| Measurement Range | ORP |
| Reference Cell Type | single, Ag/AgCl |
| Junction Type/Flow Rate | ceramic, single / 15-20 μL/h |
| Refill Electrolyte | 3.5M KCl + AgCl |
| Body Material | glass |
| Tip / Shape | platinum pin |
| Matching Pin | no |
| Max. Pressure | 0.1 bar |
| Temperature Operating Range | -5 to 70°C (23 to 158°F) |
| Body Length/Overall Length | 150 mm / 205.5 mm |
| Temperature Sensor | no |
| Outer Diameter | 12 mm |
| Cable | coaxial; 1 m (3.3’) |
| Connector Type | BNC |
| Amplifier | no |
| Recommended Use | general purpose, laboratory general purpose, ORP titrations |
| ORP Sensing Type | Platinum |
Gel Filled PEI Body ORP Electrode with BNC Connector
Specifications
×
| SKU | HI3230B |
|---|---|
| Product Name | Gel Filled PEI Body ORP Electrode with BNC Connector - HI3230B |
| Quote Required | Yes |
| Measurement Range | ORP |
| Reference Cell Type | single, Ag/AgCl |
| Junction Type/Flow Rate | ceramic, single |
| Type of Electrolyte | gel |
| Body Material | PEI |
| Tip / Shape | platinum pin |
| Matching Pin | no |
| Max. Pressure | 2 bar |
| Temperature Operating Range | -5 to 70°C (23 to 158°F) |
| Body Length/Overall Length | 120 mm / 163.5 mm |
| Temperature Sensor | no |
| Outer Diameter | 12 mm |
| Cable | coaxial; 1 m (3.3’) |
| Connector Type | BNC |
| Amplifier | no |
| Recommended Use | municipal water, quality control |
| ORP Sensing Type | Platinum |
Digital Glass Body pH Electrode for Hydrocarbons and Solvents
Specifications
×
| SKU | HI10430 |
|---|---|
| Product Name | Digital Glass Body pH Electrode for Hydrocarbons and Solvents - HI10430 |
| Quote Required | Yes |
| Measurement Range | pH |
| Reference Cell Type | double |
| Junction Type/Flow Rate | ceramic, triple / 40-50 μL/h |
| Refill Electrolyte | 3.5M KCl |
| Body Material | glass |
| Tip / Shape | spheric (dia |
| Matching Pin | no |
| Max. Pressure | 0.1 bar |
| Temperature Operating Range | -5 to 100°C (23 to 212°F) |
| Body Length/Overall Length | 120 mm / 175.5 mm |
| Temperature Sensor | yes |
| Outer Diameter | 12 mm |
| Cable | coaxial; 1 m (3.3’) |
| Connector Type | 3.5 mm connector |
| Amplifier | no |
| Recommended Use | hydrocarbon, low conductivity solutions, paints, sea water, solvents, strong acid and base, tris buffer |
Digital Glass Body pH Electrode with Clogging Prevention System
Specifications
×
| SKU | HI10480 |
|---|---|
| Product Name | Digital Glass Body pH Electrode with Clogging Prevention System (CPS™) - HI10480 |
| Quote Required | Yes |
| Measurement Range | pH |
| Reference Cell Type | double |
| Junction Type/Flow Rate | open, CPS technology |
| Refill Electrolyte | 3.5M KCl |
| Body Material | glass |
| Tip / Shape | spheric |
| Matching Pin | no |
| Max. Pressure | 0.1 bar |
| Temperature Operating Range | 0 to 80°C (32 to 176°F) |
| Body Length/Overall Length | 120 mm / 175.5 mm |
| Temperature Sensor | yes |
| Outer Diameter | 12 mm |
| Cable | coaxial; 1 m (3.3’) |
| Connector Type | 3.5 mm connector |
| Amplifier | no |
| Recommended Use | application specific purpose, samples with suspended solids, wine |
| Notes | Compatible Meters |