Checker
Copper High-Range Checker® HC
Model No : HI702
Silica Checker
Model No : HI705
Total chlorine Checker HC® colorimeter: Range 0.00 to 3.50 ppm (mg/L)
Model No : HI711
Bromine Checker (0.0 to 9.99 ppm)
Model No : HI716
Phosphate High-Range Checker® HC
Model No : HI717
Iodine Checker HC® colorimeter: Range 00.0 to 12.5 ppm (mg/L)
Model No : HI718
Magnesium Hardness Checker
Model No : HI719
Iron Checker HC® colorimeter: Range 0.00 to 5.00 ppm (mg/L)
Model No : HI721
Fluoride LR Checker HC®, 0.00 to 2.00 ppm
Model No : HI729
Alkalinity Checker for drinking water
Model No : HI775
Copper High-Range Checker® HC
Specifications
×
SKU | HI702 |
---|---|
Product Name | Copper High-Range Checker® HC |
Quote Required | Yes |
Copper Range | 0.00 to 5.00 ppm |
Copper Resolution | 0.01 ppm |
Copper Accuracy | ±0.05 ppm ±5% of reading |
Copper Method | adaptation of the EPA method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample |
Photometer/Colorimeter Light Source | LED @ 575 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI702 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual. |
Silica Checker
Specifications
×
SKU | HI705 |
---|---|
Product Name | Silica Low-Range Checker® HC - HI705 |
Quote Required | Yes |
Silica Range | 0.00 to 2.00 ppm |
Silica Resolution | 0.01 ppm |
Silica Accuracy | ±0.03 ppm ±5% of reading |
Silica Method | adaptation of the ASTM D859, heteropoly blue method |
Photometer/Colorimeter Light Source | LED @ 610 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI705 Checker® is supplied with (2) cuvettes with caps, silica LR reagent starter kit for 12 tests (1 bottle of reagent A, 12 packets of reagent B, and 12 packets of reagent C), battery, and instructions. |
Total chlorine Checker HC® colorimeter: Range 0.00 to 3.50 ppm (mg/L)
Specifications
×
SKU | HI711 |
---|---|
Product Name | Total chlorine Checker HC® colorimeter: Range 0.00 to 3.50 ppm (mg/L) |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Total Chlorine Range | 0.00 to 3.50 ppm |
Total Chlorine Resolution | 0.01 ppm |
Total Chlorine Accuracy | ±0.03 ppm ±3% of reading |
Chlorine Method | adaptation of USEPA method 330.5, DPD method |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after two minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI711 Checker® is supplied with (2) sample cuvettes with caps, total chlorine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide. |
Hsn Code | 90275010 |
Bromine Checker (0.0 to 9.99 ppm)
Specifications
×
SKU | HI716 |
---|---|
Product Name | Bromine Checker (0.0 to 9.99 ppm) |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Bromine Range | 0.00 to 8.00 ppm |
Bromine Resolution | 0.01 ppm |
Bromine Accuracy | ±0.08 ppm ±5% of reading @ 25 oC |
Bromine Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample. |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 86.0mm x 61mm x 37.5mm (3.4" x 2.4" x 1.5”) |
Ordering Information | HI716 Checker® is supplied with (2) sample cuvettes with caps, bromine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide. |
Hsn Code | 90275010 |
Phosphate High-Range Checker® HC
Specifications
×
SKU | HI717 |
---|---|
Product Name | Phosphate HR Checker HC®, 0.0 to 30.0 ppm (mg/L) |
Quote Required | No |
Phosphate Range | 0.0 to 30.0 ppm |
Phosphate Resolution | 0.1 ppm |
Phosphate Accuracy | ±1.0 ppm ±5% of reading |
Phosphate Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Heteropolymolybdenum Blue method. |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI717 Checker® is supplied with (2) sample cuvettes with caps, phosphate HR reagent starter kit for 20 tests (1 bottle of phosphate HR reagent A, 20 packets of phosphate HR reagent B), battery, instructions and quick start guide. |
Hsn Code | 90275010 |
Iodine Checker HC® colorimeter: Range 00.0 to 12.5 ppm (mg/L)
Specifications
×
SKU | HI718 |
---|---|
Product Name | Iodine Checker HC® colorimeter: Range 00.0 to 12.5 ppm (mg/L) |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Iodine Range | 0.0 to 12.5 ppm |
Iodine Resolution | 0.1 ppm |
Iodine Accuracy | ±0.1 ppm ±5% of reading |
Iodine Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI718 Checker® is supplied with (2) sample cuvettes with caps, iodine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide. |
Hsn Code | 90275010 |
Magnesium Hardness Checker
Specifications
×
SKU | HI719 |
---|---|
Product Name | Magnesium Hardness Checker |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Hardness, Magnesium Range | 0.00 to 2.00 ppm |
Hardness, Magnesium Resolution | 0.01 ppm |
Hardness, Magnesium Accuracy | ±5% of reading ± 0.20 ppm |
Hardness, Magnesium Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA colorimetric method. The reaction between magnesium and reagents causes a reddish-violet tint in the sample. |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 86.0 mm x 61.0 mm x 37.5 mm (3.4" x 2.4" x 1.5") |
Ordering Information | HI719 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (50 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual. |
Hsn Code | 90275010 |
Iron Checker HC® colorimeter: Range 0.00 to 5.00 ppm (mg/L)
Specifications
×
SKU | HI721 |
---|---|
Product Name | Iron Checker HC® colorimeter: Range 0.00 to 5.00 ppm (mg/L) |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Iron Range | 0.00 to 5.00 ppm |
Iron Resolution | 0.01 ppm |
Iron Accuracy | ±0.04 ppm ±2% of reading |
Iron Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after three minutes of non-use and two minutes after reading |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI721 Checker® is supplied with (2) sample cuvettes with caps, iron reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide. |
Hsn Code | 90275010 |
Fluoride LR Checker HC®, 0.00 to 2.00 ppm
Specifications
×
SKU | HI729 |
---|---|
Product Name | Fluoride LR Checker HC®, 0.00 to 2.00 ppm |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Fluoride Range | 0.00 to 2.00 ppm |
Fluoride Resolution | 0.01 ppm |
Fluoride Accuracy | ±0.10 ppm ±5% of reading |
Fluoride Method | adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method. |
Photometer/Colorimeter Light Source | LED @ 575 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI729 Checker® is supplied with (2) sample cuvettes with caps, fluoride LR reagent starter kit for 5 tests (1 bottle of fluoride LR reagent, 30 mL), (1) 1 mL syringe with tip, battery, instructions and quick start guide. |
Hsn Code | 90275010 |
Alkalinity Checker for drinking water
Specifications
×
SKU | HI775 |
---|---|
Product Name | Alkalinity Checker for drinking water |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
Alkalinity Range | 0 to 500 ppm |
Alkalinity Resolution | 1 ppm |
Alkalinity Accuracy | ±5 ppm (mg/L) ±5% of reading |
Alkalinity Method | colorimetric method. |
Photometer/Colorimeter Light Source | LED @ 610 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”) |
Ordering Information | HI775 Checker® is supplied with (2) sample cuvettes with caps, alkalinity reagent starter kit for 25 tests (1 bottle of alkalinity reagent), (1) 1 ml syringe and tip), battery, instructions and quick start guide. |
Hsn Code | 90275010 |