Advanced benchtop meters


Advanced pH/ORP Benchtop Meter- HI6221-02
Model No : HI6221

Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®)
Model No : HI6421
Advanced pH/ORP Benchtop Meter- HI6221-02
Specifications
×
SKU | HI6221-02 |
---|---|
Product Name | Advanced pH/ORP Benchtop Meter- HI6221-02 |
Quote Required | No |
pH Range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to |
pH Range | 20.000 pH |
pH Resolution | 0.1 pH; 0.01 pH; 0.001 pH |
pH Accuracy | ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) |
mV Range | ±2000.0 mV |
mV Resolution | 1 mV; 0.1 mV |
mV Accuracy | ±0.2 mV ±1 last significant digit |
Temperature Range | -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K |
Temperature Resolution | 0.1 °C / 0.1 °F / 0.1 K |
Temperature Accuracy | ±0.2 °C / ±0.4 °F / ±0.2 K |
Relative mV offset range | ±2000.0 mV |
pH Calibration Calibration points | Up to 5 |
pH Calibration Type | Automatic; Semiautomatic; Manual |
pH Calibration Standard buffers | Hanna and NIST |
pH Calibration Standard buffers | pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45" |
pH Calibration Custom buffers | Up to 5 |
pH Calibration Custom group | Up to 5 |
pH Calibration 1st calibration point | Offset or Points (user setting) |
pH Calibration Reminder | Disabled |
pH Calibration Reminder | Daily |
pH Calibration Reminder | Periodic |
Temperature Compensation | Automatic or Manual |
Reading Modes | Direct; Direct/Autohold |
Reading Stability criteria | Accurate; Medium; Fast |
Reading Isopotential | 7.000 or 4.010 |
Reading Sampling rate | 1000 ms |
pH Views Basic | Measurement (pH, mV, Rel.mV, Abs.mV) |
pH Views Basic | Temperature, Stability status |
pH Views Simple GLP | Basic view information |
pH Views Simple GLP | Last calibration date, electrode offset, average slope, and electrode condition |
pH Views Full GLP | Simple GLP information and calibration point details |
pH Views Table | Measurements updated every second are displayed in table |
pH Views Graph (Plot) | pH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology) |
Logging Type | Automatic, Manual, Autohold |
Logging Number of records | 50 000 maximum per file / Stores at least 1 000 000 data points per user" |
Logging Automatic interval | 1, 2, 5, 10, 30 seconds |
Logging Automatic interval | 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes" |
Logging Sample ID | Incremental mode |
Logging Export option | .csv file format |
Logging Export option | Users Up to 9 users and admin. account (default) |
Connectivity USB-A | 2 ports for keyboard input or USB thumb drive |
Connectivity USB-C | 1 port for PC connectivity and USB-C type thumb drive |
Connectivity Wi-Fi & Ethernet | FTP / Web server Log transfer and download Email |
Connectivity RS232 | Connecting peripherals |
Power supply | DC adapter 100-240AC to 24VDC 2.5A |
Environment | 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing |
Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
Weight | Approximately 1.2 kg (2.65 lbs.) |
Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®)
Specifications
×
SKU | HI6421 |
---|---|
Product Name | Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®) - HI6421 |
Stock Status Message | Pre-order, Ships within 7-8 Weeks |
Quote Required | No |
DO (HI7641133 Optical probe) Range | 0.00 to 50.00 mg/L (ppm) concentration; 0.0 to 500.0 % saturation |
DO (HI7641133 Optical probe) Resolution | 0.01 mg/L (ppm); 0.1 % saturation |
DO (HI7641133 Optical probe) Accuracy | from 0.00 to 20.00 mg/L (ppm) 1.5 % of reading or ± 0.01 mg/L (ppm), whichever is greater from 20.00 to 50.00 mg/L (ppm) ±5 % of reading from 0.0 to 200.0 % saturation ± 1.5 % of reading or ± 0.1 %, whichever is greater from 200.0 to 500.0 % saturation ±5 % of reading |
Barometric Pressure Range | 450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm |
Barometric Pressure Resolution | 1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm |
Barometric Pressure Accuracy | ±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least significant digit |
Temperature Range | −20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K |
Temperature Resolution | 0.1 °C; 0.1 °F; 0.1 K |
Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
DO Calibration Points | One or two points automatic calibration at 100% (8.26 mg/L) and 0% (0 mg/L). Single point manual using a value entered by the user in % saturation or mg/L. |
DO Calibration Standards | 0 and 100% saturation |
DO Calibration Reminder | Disabled Daily |
Temperature Compensation | Automatic or Manual |
Salinity Compensation | Automatic from 0 to 70 PSU (manually set) 0.0 to 70.0 % / 0.0 to 45.0 g/L / 0.0 to 42.0 psu |
Reading Modes | Direct Direct/Autohold |
Reading Stability criteria | Accurate Medium Fast |
Reading Isopotential | 7.000 or 4.010 |
Reading Sampling rate | 1000 ms |
DO Views Basic | Measurement (DO, Temperature) Stability status |
DO Views Simple | GLP Basic view information Last calibration date, offset, average slope |
DO Views Full | GLP Simple GLP information and calibration point details |
DO Views Table | Measurements updated every second are displayed in table |
DO Views Graph (Plot) | Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) |
Logging Type | Automatic, Manual, Autohold |
Logging Number of records | 50 000 maximum per file Stores at least 1 000 000 data points per user |
Logging Automatic interval | 1, 2, 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
Logging Sample ID | Incremental mode |
Logging Export option | .csv file format |
Users | Up to 9 users and the default administrator account |
Connectivity USB-A | 2 ports for keyboard input or USB thumb drive |
Connectivity USB-C | 1 port for PC connectivity and USB-C type thumb drive |
Connectivity Wi-Fi & Ethernet | FTP / Web server Log transfer and download Email |
Connectivity RS232 | Connecting peripherals |
Power supply | DC adapter 100-240AC to 24VDC 2.5A |
Environment | 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing |
Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
Weight | 1.2 kg (26.5 lbs.)1 |