Out of stock

Pool Line Cleaning Solution for Oils and Lotions (500 mL) – HI70774L

HI70774L Pool Line Cleaning Solution for Oils and Lotions is a highly effective cleaning solution formulated for the proper cleaning of pH and ORP electrodes. Electrodes can become coated with oils found in swimming pools, hot tubs, and spas. The coating on an electrode will cause a change in the reading and will lead to inaccurate results. The HI70774L is formulated specifically to clean oils from the sensitive surface of pH and ORP electrodes. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

  • Specially formulated cleaning solution to remove oils and lotions
  • Air tight bottle with tamper-proof seal to ensure quality
  • Expiration date and lot number clearly marked on the bottle

114.00 AED

Estimated delivery: 15 - 16 January

Inquire Now
SKU:HI70774L

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result as any changes to the surface occurs.The HI70774L Pool Line Cleaning Solution is ideal for Service Technicians in the routine maintenance of process pH and ORP probes used in monitoring and control of swimming pools, hot tubs, and spas. The cleaning solution will ensure that the probes are cleaned of any oils that have accumulated on the probes. The proper maintenance and calibration of pH and ORP probes is critical when using with process meters for maintaining desired set points.

 Screen Shot 2015 01 08 at 3.20.38 PM

Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI70774L cleaning solution for 15 to 20 minutes will dissolve any oily residues. The probe should then be placed in storage solution for 15 minutes to allow for hydration of a pH or ORP electrode. After hydration then the probe can be calibrated.

Specifications

SKUHI70774L
NamePool Line Cleaning Solution for Oils and Lotions (500 mL) – HI70774L
Descriptioncleaning solution for oils and lotions
Packagebottle
Quantity1
Size500 mL

Manuals

Pool Line Cleaning Solution for Oils and Lotions (500 mL) – HI70774L

Bestsellers

HI7061L General Purpose Cleaning Solution (500 mL)

61.00 AED
HI7061L is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
  • Specially formulated for cleaning electrodes
  • Air tight seal to ensure quality
  • Expiration date and lot number

Digital Glass Body pH Electrode for General Purpose - HI11310

638.00 AED
The HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes. The HI11310 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
  • Built-In Microchip
  • Spherical Glass Tip
  • Double Junction Reference
  • 3.5 mm Connector
Inquire Now

GroLine pH/EC/TDS Multiparameter Probe (Inline)

989.00 AED
The HI1285-9 inline multiparameter probe measures pH, EC/TDS, and temperature in one convenient, rugged probe. Use with the HI981421 GroLine Monitor to provide around-the-clock, continuous monitoring of pH, conductivity (EC & TDS), and temperature in hydroponic nutrient solutions.
  • In-line pH, EC, & TDS probe with exclusive PTFE non-clogging membrane.
  • Built-in temperature sensor ensures fast, accurately compensated readings even during sudden temperature fluctuations.
  • Specialized for hydroponics with a renewable junction for extended life.
Inquire Now

Compact Magnetic Mini-Stirrer (Black) - HI180-1

306.00 AED
HI180 are a family of lightweight and inexpensive magnetic mini-stirrers. The stirrers are compact and easy to handle, requiring very little space. HI180 mini-stirrers are available in 11 colors, allowing easy recognition on crowded benchtops. Lightweight design Speedsafe™ mechanism Adjustable speed control
Inquire Now

edge® Multiparameter EC/TDS/Salinity Meter - HI2030

2,682.00 AED
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

Phosphate High-Range Checker® HC Calibration Check Set - HI717-11

51.00 AED
The Phosphate High-Range Checker® HC Calibration Check Set - HI717-11 provides a simple solution to validating the Phosphate High-Range Checker® HC - HI717 that has a range of 0.0 to 30.0 ppm (mg/L). This high-quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a Certificate of Analysis. The Certificate of Analysis provides the lot number, reference values and expiration date for traceability when certifying the Checker® HC.
  • Supplied with Certificate of Analysis
  • Standard value of 15.0 ±1.5 ppm phosphate @ 25℃
  • Reusable with long shelf life stability

GroLine pH 10.01 Calibration Buffer (500 mL) - HI7010-050

61.00 AED
HI7010-050 is a high quality pH 10.01 calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and have an air tight, tamper-proof seal to ensure the quality of the solution. This technical calibration buffers has been specially formulated with expiration 2 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.02 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle