Out of stock

Copper Half-Cell Ion Selective Electrode (ISE) – HI4008

The HI4008 is a solid state, half-cell ion selective electrode (ISE) for the determination of cupric ions (Cu2+) in solution. The mixed cupric sulfide/silver sulfide sensing pellet produces a potential change due to the cupric ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.

The HI4008 is ideal for a variety of applications in plating, wastewater, and industrial processes.

  • Solid state sensor
  • Detection from 0.065 to 6, 355 mg/L Cu2+
  • For use with HI5315 reference half-cell

3,300.00 AED

Inquire Now
SKU:HI4008

The HI4008 cupric ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed cupric sulfide/silver sulfide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.

Hanna’s solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.

For the HI4008 to measure cupric ions accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the HI4000-00 ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free cupric ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4008 cupric solid state ISE can measure from 1µM (0.065 mg/L) to 0.1M (6, 355 mg/L).

Conversion Table for Cu2+

Multiply

moles/L (M) to ppm (mg/L)

6.354 x 104

ppm (mg/L) to M (moles/L)

1.574 x 10-4

Features at-a-glance

Fixed Sensing Modules – Solid state half-cell ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the HI4008 cupric half-cell by a fixed sensing module for ease of use.

Durable Epoxy Body – The probe body of the cupric half-cell ISE is composed of durable epoxy resin.

BNC Connection – The HI4008 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.

Theory of Operation

A solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.

Specifications

SKU HI4008
Name Copper Half-Cell Ion Selective Electrode (ISE) – HI4008
Description solid state; half-cell
Measurement Range Curpic (Cu2+) 0.1M to 1 10-6M, 6,355 to 0.065 mg/L (ppm)
Temperature Range 0 to 80 °C
Body Material epoxy
Optimum pH Range pH 3 to 7
Body Length/Overall Length 120 mm
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Notes Approximate Slope +27 mV

Manuals

Copper Half-Cell Ion Selective Electrode (ISE) – HI4008

Bestsellers

HI7004L/C pH 4.01 Calibration Solution (500 mL)

89.00 AED
HI7004L/C is a premium quality pH 4.01 calibration solution that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • Supplied with Certificate of Analysis
  • Accuracy of ±0.01 pH @ 25℃
  • Temperature chart of the actual pH value at various temperatures printed on each bottle

HI7032L 1382 mg/L (ppm) TDS Calibration Solution (500mL Bottle)

61.00 AED
HI7032L is a premium quality 1, 382 mg/L (ppm) TDS calibration solution that is prepared against a NIST traceable potassium chloride solution. Hanna TDS solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of TDS calibration solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
  • 1, 382 mg/L (ppm) TDS calibration solution
  • Temperature chart of the actual µS/cm value at various temperatures printed on each bottle
  • Air tight bottle with tamper-proof seal to ensure quality

HI7021L 240 mV @ 25°C ORP Test Solution (500 mL)

114.00 AED
HI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.
  • Prepared with reagent grade chemicals
  • Allows for a quick check of your ORP electrode
  • Air tight bottle with tamper-proof seal to ensure quality

COD Low Range Reagent Vials, EPA Method (25 tests) - HI93754A-25

250.00 AED
The HI93754A-25 are barcode reagent vials that follow the EPA approved method for the low range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
  • Pre-dosed reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability
  • *This product is classified as Dangerous Goods and can only be shipped via ground. For Professional Use Only.

    Refillable Double Junction pH Electrode with BNC Connector - HI1043B

    788.00 AED
    The HI1043B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the pH sensing portion is made with high temperature glass. This design consideration is ideal for hydrocarbons, paints, solvents, high conductivity samples, strong acids and bases, and for measuring samples at elevated temperatures.
    • Refillable Electrode
    • Double Junction Design
    • High Temperature Glass

    Alkalinity Chemical Test Kit - HI3811

    206.00 AED
    The HI3811 is a chemical test kit that measures alkalinity by titration with hydrochloric acid. The HI3811 is supplied complete with all of the reagents and equipment necessary to perform approximately 110 tests.
    • Pre-made reagents for ease of use
    • All reagents marked with expiration date and lot number for traceability
    • Manual titration performed with color indicator

    Free Chlorine Reagents (100 tests) - HI93701-01

    101.00 AED
    The HI93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.
    • Pre-made reagents for ease of use
    • Prepared with high-purity chemicals
    • Marked with expiration date and lot number for traceability
    Back to Top
    Whatsapp
    Product has been added to your cart